Laserfiche WebLink
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name. am-mrFrST PAE%8I T IE PU= Builder Name. DON BROWN CINST. <br /> street 583713Ttt-ST Permit Office- ZEPHYRHILLS <br /> City,State,Zip: ZEPHYRHILLS FL,33542 Pen it Number. 1 01718 <br /> Owner PREMIER Jurisdiction: 61600 <br /> Design Location: FL, Tampa County:: Pasco(Florida Climate Zone 2 <br /> 1. New construction or e)dsft New(From Plans) 9. WaO Types(1617.3 sqfL) Insulation Area <br /> 4 or multiple family Single-family 2. Single family a.Concrete Bb*-Int Instill,Exterior R--5.0 1229.30 ftz <br /> b.Frame-Wood,Adjacent R=11.0 288.00 ft2 <br /> 3. Number of units,if multiple family I c.WA R= fI2 <br /> 4. Number of Bedroans 3 d.WA R-- ft2 <br /> 5. Is this a worst case? No 10.Ceiling Types(1739.0 sqfL) Insulation Area <br /> a Under Attic(Vented) R--W.0 1739.00 fe <br /> 6. Conditioned floor area above grade(ft) 1739 b.NIA R-- ff, <br /> Conditioned flow area below grade(ft.) 0 G.WA R= ft2 <br /> 11.Ducts R its <br /> 7. Windows(143.7 sqfL) Description Area a.Sup:Attic,Ret Main,AH:Main 6 347.8 <br /> a. U-Factor SgI,U=0.30 143.68 fix <br /> SHGC: SHGC--0.23 <br /> b. U-Factor: NIA. to 12. Cooling system kBhAr Efficiency <br /> SHGC: a.Central Unit 34.4 SEER:14.00 <br /> c. U-Factor NIA fe <br /> SHGC: 13. Heaft systems kBbAr Efficiency <br /> d. U-Factor. NIA fie a Electric Heat Pump 32.8 HSPF-820 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.333 fL <br /> Area Weighted Average SHGC. 0230 14.Hot water <br /> system <br /> 8. Floor Types (1739.0 sqfL) . Insulation Area a. Electric Cap:-40 gallons <br /> a. Slab-On-Grade Edge Insulation R=0.0 1739.00 ftZ b. Conservation fealunes EF.,0.920 <br /> b.NIA R= ft2 None <br /> c.NIA R= f12 15.Credits None <br /> Total Proposed Modified Loads'. 50.27 PASS <br /> Glass/Floor Area: 0.083 Total Baseline Loads. 52.49 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 02ktE S7, <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. <br /> Before construction is completed PREPARED BY: 4r-�- pleted <br /> DATE: V1 this building will be inspected for <br /> compliance with Section 553.908 x <br /> ....... ....... <br /> I hereby certify that this tWilding,as designed,is in compliance Florida Statutes. <br /> with the Florida Energy t4de. WE <br /> OWNER/AGENT- BUILDING OFFICML <br /> DATE: DATE: <br /> - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure quallifies as <br /> certified factory-seated In accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402-4.1.1 and this project requires an <br /> envelope leakage tog report with envelope leakage no greater than 6.00 ACH60(R402AI.2). <br /> 5/1=18 9:27 AM EnergyGaugeO USA- FIaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 <br />