Laserfiche WebLink
stem z5. �ua a i c u t ns. 1z u m m 84 <br /> Re=�s-du-n`fa" oad - V'Jhole 11-110-use C-',ornno -rent D-4- s <br /> C, ` U. , I <br /> PREMIER Project Title: <br /> 5637 13TH ST 5637 13TH ST PREMIER MJ TJLII 5-18 <br /> ZEPHYRHILLS , FL 33542 <br /> ORIENTATION NORTH HVAC VALUES SEMI TIGHT 5/1/2018 <br /> Reference City:Tampa, FL Temperature Difference: 17.OF(TMY3 99%) Humidity difference: 54gr. <br /> Type Overhang Window Area(sqft) HTM Load <br /> Window Panes sHGC U InSh IS Ornt Len Hgt Gross Shaded Unshaded Shaded Unshaded <br /> 1 1 NFRC 0.23,0.30 No No W 1.3ft 1.0ft 4.9 02 4.7 10 27 130 Btuh <br /> 2 1 NFRC 0.23,0.30 No No S 1.3ft. I.Ok 25.3 25.3 0.0 10 11 253 Btuh <br /> 3 1 NFRC 0.23,0.30 No No S 1.31t 1.011. 16.5 16.5 0.0 10 11 165 Btuh <br /> 4 1 NFRC 0.23,0.30 No No S 1-3ft. 1.0ft. 40.0 40.0 0.0 10 11 400 Btuh <br /> 5 1 NFRC 0.23,0.30 No No E 1.3ft 1.0ft. 33.1 0.7 32.4 10 27 894 Btuh <br /> 6 1 NFRC 0.23,0.30 No No E 1.3% 1.01L 7.3 0.2 7.1 10 27 197 Btuh <br /> 7 1 NFRC 0.23,0.30 No No N 1.3k 1.01t. 16.5 0.0 16.5 10 10 165 Btuh <br /> Window Total 1 144(sqft) 2205 Btuh <br /> Walls Type U-Value R-Value Ama(sqft) HTM Load <br /> Cav/Sheath <br /> 1 Concrete BIKHollow-E)d 0.13 5.0/0.0 38.9 1.7 67 Btuh <br /> 2 Frame-Wood-Adj 0.09 11.0/0.0 110.4 1.6 178 Btuh <br /> 3 Frame-Wood-Adl 0.09 11.010.0 160.0 1.6 258 Btuh <br /> 4 Concrete BkHollow-E)d 0.13 5.0/0.0 195.1 1.7 334 Btuh <br /> 5 Concrete BlkHollow-E)d 0.13 5.0/0.0 241.3 1.7 413 Btuh <br /> 6 Concrete BlkHollow-E)d 0.13 5.0/0.0 359.6 1.7 615 Stuh <br /> 7 Concrete BkHollow-E)d 0.13 5.0/0.0 127.5 1.7 218 Btuh <br /> 8 Concrete BkHollow-E)d 0.13 5.010.0 64.0 1.7 109 Btuh <br /> Wall Total 1297(Sqft) 2192 Btuh <br /> Doors Type Area(sqft) HTM Load <br /> I Wood-Exterior 19.8 12.9 254 Btuh <br /> 2 Wood-Garage 17.6 12.9 226 Btuh <br /> 3 Wood-Exterior 39.5 12.9 509 Btuh <br /> ,Door Total 77(sqft) 989 Btuh <br /> Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load <br /> 1 Vented Mc/LightlShirigle 0.032 30.010.0 1739.0 1.34 2326 Btuh <br /> Ceiling Total 1739(sqft) 2326 Btuh <br /> Floors Type R-Value Size HTM Load <br /> 1 Slab On Grade 0.0 1739(ftlmirrreter) 0.0 0 Btuh <br /> Floor Total 1739.0(sqft) 0 Btuh <br /> Envelope Subtotal: 7712 Btuh <br /> Infiltration Type Average ACH Volume(cuft)Wall Ratio CFM= Load <br /> Natural 0.63 13912 1 146.1 2731 Btuh <br /> Internal Occupants Btuh/occupant Appliance Load <br /> gain 4 X 230 + 7000 7920 Btuh <br /> Sensible Envelope Load: 18363 Btuh <br /> Duct load Average sealed„suppWR6.oAft),Re"R&o-condi) (DGM of 0.202) 3704 Btuh <br /> Sensible Load All Zones 22067 Efth <br /> EnergyGauge9/USRCZBv6.0 Page 1 <br />