Laserfiche WebLink
Single Family Dwelling. <br /> Plan Review Comments <br /> 1: F.F.E. shall be a minimum of.8" above.the road elevation and an engineered site plan. <br /> 2.. Lots shall be graded to comply with R401.3 of the F.R.C. <br /> 3. Compaction test required if 24" or more of-fill dirt is brought in at any one place: <br /> 4: 'Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.-O.W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material: <br /> 6. All setbacks.shall be met: . <br /> 7. All property:markers shall be.uncovered and marked at time of first inspection: <br /> 8. All A.D.A. requirements shall be met. <br /> 9. No electric, plumbing, mechanical, or framing shall be covered without an:inspection and <br /> approval first. <br /> 10. All Garages shall comply with-section R302.6 of the.F.B.0 (Fire S:eparatio.4, <br /> 11. Appliances shall not.be installed in a location where subject'to,mechanical damage unless <br /> protected by.approved barriers. M303.4-of the F.B:C <br /> 12. Water heaters shall comply:with section P607.3'of the F.B.C. <br /> 13. Foundation supports-for-A/C.units shall be raised at least 3'.' above finished grade. M1308.1 <br /> 14. Return airin all-bedrooms..F.B.C. M1620.4 <br /> 15. Smoke detectors are to b-e installed in accordance with R313.1 of the F.B.C. <br /> 16: All glazing requirements are to be in accordance with R308.4.of the F.B.C. <br /> 17. All means of egress are to be in accordance with R311 of the KB.C. .: <br /> 18. "Green gypsum.board''shall not be used: a backer.in showers or tubs. R702.4:2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all.locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in-new:construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing, mechanical, and:electricai shall be separate from unit,to.unit: This includes all <br /> ;underground plumbing and electric: <br /> 22. A112011.N:E:C: Codes will be enforced: <br /> 23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2011 N:E.0 <br /> 24: In accordancemith_the Land Development Code; lots shall be sodded before final at least 10 <br /> feet_around the structure. <br /> 25. A.copy of the eizei:6 cacls shall be with pe.rmitat all dines. <br /> 26 Com of rtnal insulation'report shall be provided with.Permit before.fnaL <br /> RE E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6 h Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2011) <br />