CRESTVIEW HILLS
Building Department - Doc Type
Permit
Permit #
18-19743
Building Department - Name
CUIZON,DANNY & NARITA
Address
7652 JENO ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIRE SAFETY REQUIREMENTS P-88 1 27 <br /> N EXTERIOR-MOUNTED DC CONDUITS,WIRING SYSTEMS, <br /> AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL <br /> 1 BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, <br /> HIP,OR VALLEY,AND FROM THE HIP OR VALLEY AS <br /> DIRECTLY AS POSSIBLE TO AN OUTSIDE WALL TO <br /> REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION <br /> OPPORTUNITIES(NFPA 111.12.2.2.4.1) <br /> ROOF ACCESS POINTS SHALL BE DEFINED AS AREAS <br /> a. - WHERE FIRE DEPARTMENT LADDERS ARE NOT PLACED <br /> OVER OPENINGS(WINDOWS OR DOORS I,ARE LOCATED <br /> 2 AT STRONG POINTS <br /> DING OF BUIL CONSTRUCTION,AND W <br /> ARE IN LOCATIONS WHERE THEY WILL NOT CONFLICT E- <br /> WITH OVERHEAD OBSTRUCTIONS(TREE LIMBS,WIRES, U) O <br /> OR SIGNS).(NFPA 111.12.2.2.1.3) <br /> PHOTOVOLTAIC MODULES SHALL BE LOCATED IN A cf) L0 <br /> r MANNER THAT PROVIDES TWO 3 FT WIDE ACCESS m <br /> co <br /> PATHWAYS FROM THE EAVE TO THE RIDGE ON EACH W I-- <br /> - ROOF SLOPE WHERE THE MODULES ARE LOCATED. (n J <br /> ••• _ 4 i (NFPA 1 11.10.2.2.2.1.2) O ILL. <br /> +.•' PHOTOVOLTAIC MODULES SHALL BE LOCATED NO <br /> CLOSER THAN 1-112 FEET TO A HIP OR VALLEY IF 0-' L J <br /> _ MODULES ARE TO BE PLACED ON BOTH SIDES OF THE Q' -3 -1 <br /> { 2 A HIP OR VALLEY.WHERE MODULES ARE LOCATED ON N = <br /> `F ONLY ONE SIDE OF A HIP OR VALLEY OF EQUAL LENGTH, J L <br /> THE PHOTOVOLTAIC MODULES SHALL BE ALLOWED TO <br /> BE PLACED DIRECTLY ADJACENT TO THE HIP OR � } <br /> VALLEY.(NFPA 1 11.10.2.22.1.3) 0 <br /> 5 PHOTOVOLTAIC MODULES SHALL BE LOCATED NO LESS W ILu <br /> V <br /> THAN 3 FT BELOW THE RIDGE.(NFPA 111.10.2.2.2.2) <br /> 3 4 � <br /> FIRE SAFETY IMPLEMENTATIONS of <br /> 1 FIRE SAFETY PLAN O 3.0 FT WIDE FIRE ACCESS PATHWAY,PER NFPA 1 <br /> PV-7 SCALE:1'=20' <br /> 1 11.10.2.2.2.1.3 AND NFPA 111.10.2.2.2.1.2 <br /> O ROOF ACCESS POINT,PER NFPA 1 11.12.2.2.1.3 <br /> O ROOF ACCESS POINT,PER NFPA 111.12.2.2.1.3 <br /> O3.0 FT.WIDE SMOKE-VENTILATION SETBACK,PER NFPA <br /> 1 11.10.2.2.2.2 <br /> FIRE SAFETY <br /> PLAN <br /> DOC ID:88127-109289.1 <br /> DATE:518118 <br /> CREATOR:S.S, <br /> REVIEWER: <br /> REVISIONS <br /> PV-7 <br />