t' CO Fire Suppression <br /> & Building Products <br /> Technical Services 800-381-9312 1+1-4017781-8220 <br /> www.tyco-fire.com <br /> Series TY-FRB — 2.8, 4.2, 5.6, and 8.0 K-Factor <br /> Upright, Pendent, and Recessed Pendent Sprinklers <br /> Quick Response, Standard Coverage <br /> General Corrosion-resistant coatings, where <br /> applicable, are utilized to extend the R <br /> life of copper alloy sprinklers beyond <br /> Description that which would otherwise be obtained <br /> :7_ <br /> �.,. <br /> when exposed to corrosive atmo- <br /> The TYCO Series TY-FRB,2.8,4.2,5.6, it;E mzs its" <br /> spheres.Although corrosion-res resistant <br /> and 8.0 K-factor, Upright and Pendent <br /> coated sprinklers have passed the <br /> Sprinklers described in this data sheet <br /> standard corrosion tests of the appli- nfrr.c <br /> are quick response,standard coverage, cable approval agencies,the testing is <br /> decorative 3 mm glass bulb-type spray {, <br /> poss <br /> ible e cor- <br /> f a poss <br /> sprinklers designed for use in light or not representative o <br /> ros <br /> ordinary hazard,commercial occupan- ive atmospheres. Consequently, <br /> it is recommended that the end user � <br /> cies such as banks, hotels, and shop- <br /> ping malls. be consulted with respect to the suit- <br /> ability of these coatings for any given <br /> The recessed version of the Series TY- corrosive environment.The effects of <br /> FRB Pendent Sprinkler,where applica- ambient temperature, concentration of ?� <br /> ble, is intended for use in areas with a chemicals, and gas/chemical velocity, SA <br /> finished ceiling.This recessed pendent should be considered, as a minimum, I <br /> sprinkler uses one of the following, along with the corrosive nature of the �.,.- .- <br /> • chemical to which the sprinklers will be <br /> A two-piece Style 10 (1/2 inch NPT) p <br /> or Style 40(3/4 inch NPT) Recessed exposed. I'(: <br /> Escutcheon with 1/2 inch(12,7 mm)of An intermediate level of the Series TY- -NIA &l. i <br /> recessed adjustment or up to 3/4 inch FRB Pendent Sprinklers is detailed <br /> 19,1 mm of total adjustment from the <br /> ( ) J in Technical Data Sheet TFP356, and <br /> flush pendent position,or a Sprinkler Guards are detailed in Tech- <br /> • A two-piece Style 20 (1/2 inch NPT) nical Data Sheet TFP780. <br /> or Style 30 (3/4 inch NPT) Recessed <br /> Escutcheon with 1/4 inch(6,4 mm)of �/� <br /> recessed adjustment or up to 1/2 inch The Series TY--FRB Concealed Pendent ModellSprinkler <br /> (12,7 mm)of total adjustment from the Sprinklers described herein must be <br /> flush pendent position. installed and maintained in compliance Identification <br /> The adjustment provided by the with this document and with the appli- Number (SIN) <br /> Recessed Escutcheon reduces the cable standards of the National"Fire <br /> accuracy to which the fixed pipe drops Protection Association, in addition to <br /> to the sprinklers must be cut. the standards of any authorities having TY1131: Upright 2.8K, 1/2-NPT <br /> jurisdiction. Failure to do so may impair TY1231: Pendent 2.8K,1/2 NPT <br /> the performance of these devices. TY2131: Upright 4.2K,1/2-NPT <br /> Owners are responsible for maintaining TY2231: Pendent 4.21K,1/2-NPT <br /> their fire protection system and devices TY3131: Upright 5.61K,1/2-NPT <br /> in proper operating condition. The TY3231: Pendent 5.6K,1/2-NPT <br /> IMPORTANT installing contractor or sprinkler manu- TY4131: Upright 8.0K,3/47NPT <br /> Always refer to Technical Data facturer should be contacted with any TY4231: Pendent 8.01K,3/4"NPT <br /> Sheet TFP700 for the "INSTALLER questions. TY4831: Upright* 8.OK, 1/2-NPT <br /> WARNING' that provides cautions TY4931: Pendent* 8.OK, 1/2-NPT <br /> with respect to handling and <br /> installation of sprinkler systems and <br /> components. Improper handling and <br /> installation can permanently damage <br /> a sprinkler system or its components <br /> and cause the sprinkler to "fail to <br /> operate in a fire situation or cause it <br /> to operate prematurely. 'Eastern Hemisphere Sales Only <br /> Page 1 of 10 JULY 2010 TFP171 <br />