My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19829
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19829
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/27/2019 12:10:50 PM
Creation date
2/27/2019 12:10:41 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
18-19829
Building Department - Name
COFFLAND,JAMES
Address
39113 11TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
> z FIRE SAFETY REQUIREMENTS P-89747 <br /> N EXTERIOR-MOUNTED DC CONDUITS,WIRING SYSTEMS, <br /> AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL <br /> BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, <br /> HIP,OR VALLEY,AND FROM THE HIP OR VALLEY AS <br /> ' DIRECTLY AS POSSIBLE TO AN OUTSIDE WALL TO <br /> _ REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION <br /> OPPORTUNITIES(NFPA 1 11.12.2.2A.1) <br /> ROOF ACCESS POINTS SHALL BE DEFINED AS AREAS <br /> WHERE FIRE DEPARTMENT LADDERS ARE NOT PLACED <br /> ..'.;t '• f �•a�!''�-` OVER OPENINGS(WINDOWS OR DOORS),ARE LOCATED <br /> ";" AT STRONG POINTS OF BUILDING CONSTRUCTION,AND Lu <br /> ARE IN LOCATIONS WHERE THEY WILL NOT CONFLICT H <br /> WITH OVERHEAD OBSTRUCTIONS(TREE LIMBS,WIRES, (n <br /> L"� k �- I'I• Fe'" OR SIGNS).(NFPA 111.12.2.2.1.3) } <br /> {€ & PHOTOVOLTAIC MODULES SHALL BE LOCATED IN A C/) Lo <br /> 3 j.-=-)--�E-.-•^--'-- 3 MANNER THAT PROVIDES TWO 3 FT WIDE ACCESS uJ M <br /> 3 PATHWAYS FROM THE EAVE TO THE RIDGE ON EACH Lu <br /> ROOF(NFPA 1 OPE0WHER ZTHE MODULES ARE LOCATED. � Q —i <br /> .. .�._,. <br /> LL <br /> PHOTOVOLTAIC MODULES SHALL BE LOCATED NO LESS <br /> •;��nn 4 THAN 3 FT BELOW THE RIDGE.(NFPA 111.10.2.2.2.2) ~ J <br /> M 2 <br /> •., PV MODULES INSTALLED ON ROOF WITH IRONRIDGE <br /> ROOF MOUNTING SYSTEM.THE MOUNTING SYSTEM IS } <br /> _ 1O CLASS A FIRE RATED ON A 8112 SLOPED ROOF WHEN N M = <br /> INSTALLED WITH TYPE 1 OR 2 MODULES.THE SOLAR p <br /> WORLD SW 290 MONO IS TYPE 1. LjJ Lu <br /> ON 3.0 FT.WIDE SMOKE-VENTILATION SETBACK,PER NFPA p <br /> 1 11.10.2.2.2.2 Q <br /> O3.0 FT.WIDE FIRE ACCESS PATHWAY,PER NFPA 1 <br /> 11.10.2.2.2.1.2 <br /> 1 FIRE SAFETY PLAN Oq ROOF ACCESS POINT,PER NFPA 111.12.2.2.1.3 <br /> PV-1 SCALE:1'=20' CABLES,WHEN RUN BETWEEN ARRAYS,SHALL BE <br /> 5 ENCLOSED IN CONDUIT. <br /> FIRE SAFETY <br /> PLAN <br /> DOC ID:89747-111511-1 <br /> DATE:611/18 <br /> CREATOR:S.S. <br /> REVIEWER: <br /> REVISIONS <br /> PV-7 <br />