Laserfiche WebLink
TR1NffY 4 ER® <br /> AP.PENDix 1:ATTACHMENT REQUIREMENTS FOR WIND,UPLIFT REsisTANCE <br /> Table Deck Application Type Description Page <br /> SA Wood New,Reroof(Tear-Off),Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 4 <br /> 1B Wood New,Reroof(Tear-Off),Recover D-1 Insulated,Mechanically Attached Roof Cover 4 <br /> 1C Wood New,Reroof(Tear-Off),Recover D-3 Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 4 <br /> 1D Wood New,Reroof(Tear-Off),Recover E-1 Non-Insulated,Mechanically Attached Roof Cover 5 <br /> 1E Wood New,Reroof(Tear-Off),Recover E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 5 <br /> 1F Wood New Construction F Non-Insulated,Bonded Roof Cover 5 <br /> 2A Steel or Structural Concrete New,Reroof(Tear-Off),Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 6-7 <br /> 2B Steel or Structural Concrete New,Reroof(Tear-Off),Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 8-9 <br /> 2B Steel New,Reroof(Tear-Off),Recover C-2 Mechanically Attached Insulation,Plate-Bonded Roof Cover 10-11 <br /> 2D Steel or Structural Concrete New,Reroof(Tear-Off),Recover D-1 Insulated,Mechanically Attached Roof Cover 12-15 <br /> 2E Steel or Structural Concrete New,Reroof(Tear-Off),Recover D-2 Insulated,Mechanically Attached Roof Cover(RUSS Strips) 16 <br /> 3A Structural Concrete New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 17-18 <br /> 38 Structural Concrete New,Reroof(Tear-Off),Recover C-2 Mechanically Attached Insulation,Plate-Bonded Roof Cover 18-19 <br /> 3C Structural Concrete New,Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 19 <br /> 4A LWIC New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 20 <br /> 4A-1 LWIC over Steel New,Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 20 <br /> 4A-2 LWC over Structural Concrete New,Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 21 <br /> SA Gypsum Reroof(Tear-off) A-1 Bonded Insulation,Bonded Roof Cover 22 <br /> 6A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 23 <br /> 68 Steel Recover C-2 Mechanically Attached Insulation,Plate-Bonded Roof Cover 24 <br /> 6C Steel Recover D-1 Insulated,Mechanically Attached Roof Cover 25 <br /> 6D Steel or Structural Concrete Recover E Nan-Insulated,Mechanically Attached Roof Cover 26 <br /> 6E Various Recover F-2 New LWC over Existing Roof,Bonded Roof Cover 27 <br /> The following notes apply to the systems outlined herein: <br /> 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. <br /> Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. <br /> 2. Unless otherwise noted,fasteners and stress plates for Insulation attachment shall be as follows.Fasteners shall be of sufficient length for the following engagements: <br /> Wood Deck: Mule-Hide Drill Point Fastener or Mule-Hide HOP Fastener with Mule-Hide 3 In.Insulation Plate.Minimum%-inch steel penetration,engage the top flute of the steel deck <br /> Steel Deck: Mule-Hide Drill Point Fastener or Mule-Hide HOP Fastener with Mule-Hide 3 In.Insulation Plate.Minimum%-inch steel penetration,engage the top flute of the steel deck. <br /> Structural Concrete: Mule-Hide HOP Fastener or Mule-Hide Fluted Concrete Nail with Mule-Hide 3 in.Insulation Plate.Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the <br /> fastener manufacturer's published installation instructions. <br /> 3. Unless otherwise noted,Insulation may be any one layer or combination of polyisocyanurate,polystyrene,fiberboard,perlite and/or gypsum-based Insulation board that meets the CIA requirements of FA.C.Rule <br /> 61G20-3 and Is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. <br /> 4. Minimum 200 psi,minimum 2-Inch thick lightweight insulating concrete may be substituted for rigid Insulation board for System Type C-2(plate bonded roof cover)or Type D(mechanically attached membrane), <br /> whereby the membrane fasteners are installed through the LWIC to engage the structural steel or concrete deck.The structural deck shall be of equal or greater type,thickness and strength to the steel and concrete <br /> deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through <br /> proper codified and/or FBC Approval documentation. <br /> Exterior Research and Design,U.C.d/b/a Trinity I ERD Evaluation Report M35060.06.09-RS for FL12772-RS <br /> Certificate of Authorization N9503 0 EDITION(2017)FBC NON-HVH2 EVALUATION Revision 5:09/11/2017 <br /> Prepared by:Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(609)365-3111 Appendix 1,Page 1 of 27 <br />