My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20298
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20298
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2019 1:27:34 PM
Creation date
3/4/2019 1:27:33 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
18-20298
Building Department - Name
BARTLETT,RICHARD
Address
38408 3RD AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-�TRINIT 'tR® <br /> 16. For adhered membrane systems,side laps shall be minimum 2-inch wide sealed with min.1.5-loch heat weld. Unless otherwise noted,membrane adhesive application rates areas follows: <br /> Membrane Adhesive _ _ - - Method <br /> Mule-Hide TPO-c Mule-Hide TPO-c Bonding Adhesive(TPO-c BA) Contact(both sides) 60 ft'/gal <br /> Mule-Hide TPO-c Aqua Base 120 BA Contact(both sides) 120 ft'/gal <br /> Mule-Hide TPO-c Fleece Back Aqua Base 120 BA Wet lay(substrate) 120 ft=/gal <br /> Mule-Hide TPO-c Fleece Back Mule-Hide Helix°Low-Rise Adhesive(HELIX) Wet lay(substrate) FULL=continuous ribbons,maximum 4-Inch o.c. <br /> 17. For membrane systems attached using TPO 10-Inch Pressure-Sensitive RUSS,the underside of the membrane which comes in contact with the tape shall be primed with HP-250 Primer. The membrane shall be <br /> secured by placing the primed portion onto the tape portion of the TPO 10-inch Pressure-Sensitive RUSS and roll with a steel hand roller to ensure contact. <br /> 18. For bonded membrane systems,unless otherwise noted,reference to"Mule-Hide TPO-c"membrane below also includes"Mule-Hide TPO-c EXTRA". <br /> 19. Vapor barrier options for use over structural concrete deck followed by adhesive-applied Insulation carry the following Maximum Design Pressure(MDP)limitations.The lesser of the MDP listings below vs.those in <br /> Table 3A applies. <br /> -VAPOR BARRIER OPDDrrsi STRUCf11RAL CONLRErE DECK;FdttOWED 65'ADHESIVE-APPLI - -- _"- <br /> EDUtsuIATIONPERTAetE3'Ai <br /> Option N Primer Vapor Barrier <br /> Type Application Insulation Adhesive MDP(psf) <br /> VB-1. Carlisle CAV-GRIP Primer F5'Air&Vapor Barrier or Carlisle VapAir Seal 72STR Self-adhering HELIX(RIBBON,12-inch o.c.) -97.5 <br /> VS-2. ASTM D41 Carlisle SureMB 90TG Base or SureMB 120 TG Poly Base Torch-applied HELIX(RIBBON,12-inch o.c.) .97.5 <br /> VB-3. ASTM D41 Carlisle SureMB 90 Base or SureMB 120 Poly Base Hot-asphalt HELIX(RIBBON,12-inch o.c.) -97.5 <br /> 20. "MDP"=Maximum Design Pressure Is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. <br /> Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M15060.06.09-RS for FL12772-RS <br /> Certificate of Authorization#9503 6°1 EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 <br /> Prepared by:Robert Nleminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 3 of 27 <br />
The URL can be used to link to this page
Your browser does not support the video tag.