My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20307
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20307
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2019 1:31:14 PM
Creation date
3/4/2019 1:31:13 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
18-20307
Building Department - Name
SAVIDGE,TIMOTHY & ZUKOSKY,KATHLEE
Address
5506 18TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
G ull Cza, <br /> SUPPLY & MANUFACTURING <br /> ' U L <br /> BT <br /> y4.yllll�F,� <br /> i 'C' • • •D <br /> ENGINEER LOAD TABLE:26 Ga. GuIfPBRTM Panel over 15/32"Plywood <br /> r <br /> Buildttlgs iavlrrgsa 13oofIVlez1 f1114 �D'',Rto�Shope "f 1 ' 1 "/Zt "Fa#� Qr Roaf 1ndaeds 9 2fl- : <br /> 18C3r�sp�,E�cpO�►#��� ��5[t C�terar�i[,EncicsS�IJ��IC�mg,�;�� t r�r��lorida�B���c�in�'Co�e�#,�t7 s• Y f `` _�"�` <br /> 120 130 140 150 160 170 180 <br /> WIIND FASTENER SUBSTRATE <br /> SPEED (MIN. (MIN.15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER <br /> Penetratidoo n) SPACING SPACING SPACING SPACING SPACING SPACING SPACING <br /> ZONE 1 #9 I5x1 5" P lylnfoait)s Z4 TYPE 1 24 ,TYfE 1 24 "tY�E 24" T�'Pt` 24",7 YPE 1 24 TYPE 9 24 TYPE 1;' <br /> ZONE 2 #9-15x1.5" Plywood 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 12",TYPE 2 12",TYPE 2 <br /> u: `z- r, , <br /> .ZONE-3- #9=15 1,5 Pl`: oad 24.E TYPE:.t -2 '':7YPg 1 9Z",T1rPE.2. `9 Z"'TYPE,2 1rTY ,2 12 TYPE2•. 2 TYPES = <br /> M'p" <br /> 1.)PANEL DESCRIPTION:GULFPBRTM, MIN.26 GA., GRADE 80,36"COVERAGE, 1'114" TALL. <br /> 2.)PANEL FASTENER:#9-15X1.5"W/SEALING WASHER OR APPROVED EQ., 1/4-14X7/8" LAP SCREW MAX.24"O.C.IN PANEL SIDELAP. <br /> 3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:60.5 PSF @ 24" O.C. FASTENER SPACING TYPE I FASTENER PATTERN, 154.75 <br /> PSF @ 12" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. <br /> 4.)PLYWOOD DECKING:MIN.15/32"THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017. <br /> 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. <br /> 6.)LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85)MULTIPLIED BY 0.6 PER FLORIDA BUILDING <br /> CODE 2017. <br /> Note:Dimension(a)is defined as 10%of the minimum width of the building or <br /> ZONE2 HIP ROOF ZONE 1 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be <br /> ' --------X!, <br /> a less than either 4%of the minimum width of the building or 3 feet. <br /> TYPE 1 FASTENER PATTERN <br /> At Panel Lap <br /> RIDGE � #14 x 7/8"Lap Tek @ 24"O.C. <br /> ZONE1 \\ \ \ Ifli- <br /> /--------------------- #9-15 x 1-1/2" Continuous tape seal <br /> EAVE @ 12"-12"-12" for use on slopes <br /> ZONE a Pattern @ 24"O.C. less than 3:12. <br /> �\ GABLE ROOF 1-T <br /> —, <br /> i --- ----------------- - <br /> i —'a TYPE 2 FASTENER PATTERN <br /> l i i RIDGE #14 x 7/8"Lap Tek @ 24"o.c. <br /> — <br /> ---------------------4 -- --�"--�"�Z <br /> ZONE 1 <br /> +-- + <br /> #9-15 x 1-1/2" Continuous tape seal <br /> ------------------- <br /> @ 7"-5"-7"-5"-7" for use on slopes <br /> -ZONES EAVE Pattern @ 24"O.C. less than 3:12. <br /> FL#11651.19 R3•OCTOBER 5,2017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.