Laserfiche WebLink
SEETAEMBEDMENT SUBSTRATE (('� • <br /> SEE TABLE 1 BY OTHERS <br /> TYPICAL HEAD ANCHORAGE SEE TABLE 1 WINDOW SYSTEMS <br /> 1/4"MAX.SHIM MIN.EDGE DIST. SUBSTRATE <br /> MIN.EDGE DIST. 1900 SW 44TH AVE. <br /> SEE TABLE 1 SEE TABLE 1 SEE TABLE 1 OCALA,FLORIDA 34474///A - <br /> 1!4'MAX.SHIM WWW.CWS.CC <br /> SUBSTRATE BY OTHERS MIN.EDGE DIST. <br /> SEE TABLE 1 �� SEE TABLE 1 <br /> MIN.EMBEDMENT INSTALLATION ANCHOR o 620 PVC <br /> PERIMETER SEALANT SEE TABLE 1 SEE TABLE 1 <br /> BYINSTALLER HORIZ.SLIDER <br /> INSIDE AND OUT p MIN.EMBEDMENT <br /> SEALANTBEHIND O eo SEE TABLE NON-IMPACT <br /> FLANGE BY INSTALLER 114'MAX.SHIM o0 <br /> a Qee PERIMETER SEALANT <br /> BYINSTALLER IT <br /> PERIMETER SEALANT Qeoo <br /> BY INSTALLER INSIDE AND OUT <br /> TINSIDE AND OUT INSTALLATION ANCHOR <br /> SEALANT BEHIND SEE TABLE 1 m <br /> FLANGE BY INSTALLER SEALANT BEHIND r!) <br /> FIN BY INSTALLER <br /> INSTALLATION ANCHOR ZO <br /> SEE TABLE 1 B HORIZONTAL SECTION C HORIZONTAL SECTION rn <br /> 6 TYPICAL JAMB ANCHORAGE 6 TYPICAL FIN ANCHORAGE <br /> HEAD AND SILL SIMILAR FOR FIN INSTALLATION Z LU <br /> O Et <br /> NOTE:ADDITIONAL THRU-FRAME ANCHORS d <br /> (AS SHOWN IN DET.A/6)REQ'D AT MTG RAIL, <br /> SEE SHEET 5 ANCHOR LAYOUT. W <br /> 0 <br /> O <br /> Z <br /> SEALANT BEHIND 1/4"MAX.SHIM %jitaaoijr," <br /> FLANGE BY INSTALLER p 0 ,,`��y`PNOREW l!", <br /> PERIMETER SEALANT MIN.EMBEDMENT Q.'�GP' �`O E N S�•�2tn�: <br /> BY INSTALLER SEE TABLE 1 •�.i No .98201 ;'Jy <br /> INSIDE AND OUT <br /> :���+' <br /> SUBSTRATE BY OTHERS MIN.EDGE DIST. STATE OF <br /> .�p <br /> SEE TABLE I SEE TABLE I T�:,A' <br /> SEALANT UNDER SCREW A VERTICAL SECTION ��i�CCs R 1 Q GN <br /> HEAD BY INSTALLER 6 TYPICAL SILL ANCHORAGE pe � S,iONA���,�`� <br /> 4/27/2015 <br /> TABLE 1:APPROVED INSTALLATION FASTENERS <br /> LUCAS A.TURNER,P.E. <br /> FRAMETYPE SUBSTRATE TYPE ANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. <br /> FL PE#58201 <br /> FLANGE CONCRETE(2.0 KSI MIN.) 3/16"ITN TAPCON 1' 1-118' 1239 JABARA AVE. <br /> PERIMETER SEALANT <br /> FLANGE HOLLOW OR GROUT-FILLED CMU(117 PCF MIN.) 3/16"ITV TAPCON 1" 2" BY INSTALLER NORTH PORT,FL 34288 <br /> FLANGE CONCRETE 2.85 KSI MIN. 3116"ELCO ULTRACON 1" 1" INSIDE AND OUT PH.941-380-1574 <br /> ( ) D HORIZONTAL SECTION <br /> FLANGE HOLLOW or GROUT-FILLED CMU(ASTM C-90) 3116"ELCO ULTRACON 1-1/4" 2-1/2" 6 BOX FRAME INSTALLATION SHEET DESCRIPTION: <br /> FLANGE 2X MIN.SOUTHERN PINE(G=0.55) 3/16'ITW TAPCON 1 3/8' 7/8" SIMILAR FOR SILL AND JAMBS FOR BOX INSTALLATION INSTALLATION DETAILS <br /> OR ELCO ULTRACON <br /> FLANGE 2X MIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-3/8" 7/8' FLANGE REMOVAL NOTE:PARTIALLY OR FULLY REMOVING THE FLANGE, DRAWN BY: DATE: <br /> 16 GAUGE(0.060")MIN.STEEL STUD #10-16 HILT]KW IK-FLEXOR ITW FULL THREAD UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: EMK 04/22/15 <br /> FLANGE (33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060' 7/16" <br /> -MIN.1/4°FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED -DWG A: REV.: <br /> FLANGE 1/8"ALUM.(6063-T5 MIN.)OR #10 GRADE 5 SELF-TAPPING/ FULLTHREAD 7116„ INSIDE AND OUT,FULL PERIMETER,BY INSTALLER. CWS-1059 - <br /> 1/8"STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125" PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS SALE: <br /> FIN 2X MIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-1/2" 1/2' SHOWN FOR FLANGE WINDOWS. SHEET <br /> 1:2 60F6 <br />