My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20206
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20206
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/18/2019 10:28:19 AM
Creation date
3/18/2019 10:26:37 AM
Metadata
Fields
Template:
Building Department
Company Name
NESTLE WATERS NA INC
Building Department - Doc Type
Permit
Permit #
18-20206
Building Department - Name
NESTLE WATERS NA INC
Address
4330 20TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
13. SYSTEM POWER(continued) <br /> 13.3 Notification Appliance Power Extender Panels ®This system does not have power extender panels. . <br /> 13.3,1 Primary Power <br /> Input voltage of power extender panel(s): Power extender panel amps: <br /> Overcurrent protection: Type: Amps: ........_ <br /> Location(of primary supply panel board): <br /> Disconnecting means location: EXISTING <br /> 13.3.2 Engine-Driven Generator ®This system does not have a generator, <br /> Location of generator: <br /> Location of fuel storage: Type of fuel: <br /> 13.3.3 Uninterruptible Power System ®This system does not have a UPS. <br /> Equipment powered by a UPS system: ---- _ ----.----__,--_--__---_-- ---------_-__-- <br /> Location of UPS system: <br /> Calculated capacity of UPS batteries to drive the system,components connected to it: <br /> In standby mode(hours): In alarm mode(minutes): <br /> 13.3.4 Batteries <br /> Location: Type: Nominal voltage: ...... Amp/hour rating: _ <br /> Calculated capacity of batteries to drive the system: <br /> In standby mode(hours): _ — _ In alarm mode(minutes): <br /> ❑Batteries are marked with date of manufacture ❑Battery calculations are attached <br /> 14. RECORD OF SYSTEM INSTALLATION- <br /> Fill out after all installation is complete and wiring has been checked far opens,shorts,ground faults, and improper <br /> branching,,but before conducting operational acceptance tests. <br /> This is a:. ❑New system ®Modificationto an existing system Permit number: 13-26-21-0070-03900-0020 <br /> The system has been installed in accordance with the following requirements:(Note any or all that apply.) <br /> ®NFPA 72,Edition; -- -- - — <br /> ®NFPA 70,National Electrical Code,Article 760,Edition: <br /> ®Manufacturer's published instructions <br /> Other(specify): PLANS&SPECS PANEL.REPLACEMENT <br /> System deviations from referenced NFPA standards: <br /> Signed: Printed name: B:ROBINSON Date: 10/05/2018.: <br /> Organization: JC[ Title: TECH Phone: <br /> NFPA 72, Fig. 10.18.2.1.1 (p. 10 of 12) <br /> Copyright©2009 National Fire Protection Association.This form may be copied for individual use other than for resale,It may not be copied for commercial sale or distribution, <br />