Laserfiche WebLink
NFPA 72, Chapters I : ;.2'.)t,3) 4)i5i 6 7 8 "1 O..'l 1 (circle all that apply) -2 - <br /> NFPA 70,National Electrical Code, Article 760 <br /> Manufacturer's instructions <br /> Other(specify) <br /> Signed: Date: I Org.: <br /> 3. Record of System Operation <br /> Documentation in accordance with Inspection Testing Form,Figure 10-6 2 3 is attached: <br /> All operatio-naj features and functions of this system were tested by /f <br /> on and found to be operating properly in accordance with the requirements of: <br /> NFPA 72, Chapters .1 2;�3'( 4'(5 6 7 8 "10-' 11 (circle all that apply) <br /> NFPA 70,National Electrical Code,Article 760 <br /> ' Manufacturer's Instructions <br /> Other(specify): <br /> Signed:-," ✓ Date: —Org:—L C-- <br /> (Chapters: I —Admin., 2—Referenced Pubs, 3—Definitions, 4 Fundamentals, 5—Initiating Devices, 6—Protected <br /> Premises, 7—Notification Appliances, 8—Supervising Station, 10—Inspecting& Testing, I I—Household Alarms) <br /> 4. Signaling Line Circuits: <br /> Quantity and Class,(See NFPA 72, Table 6.6.1) of'signaling line circuits connected-to system <br /> Quantity: Style: I Class: <br /> Alarm Initiating Devices and Circuits (Use blanks to indicate quantity of devices) <br /> Quantity and Class of Initiating Device Circuits(NFPA 72 Table 6.5): <br /> Quantity: Style: Class: <br /> MANUAL <br /> a) Manual Stations: Noncoded Addressable: Transmitters:_ <br /> b) Combination Manual Fire Alarm and Guard's Tour Coded Stations: <br /> AUTOMATIC <br /> Coverage: Complete: Partial: Selective: Non-Required: <br /> a) Smoke Detectors: Ion: Photo: Addressable: <br /> b) Duct Detectors: Ion: Photo: Addressable: 'k' <br /> c) Heat Detectors: FT: RR: FT/RR: Addressable: 4 <br /> d) Sprinkler Water Flow Switches:Noncoded,: Transmitters: Addressable: <br /> e) Other(list): <br /> 6. Supervisory Signal Initiating Devices and Circuits(Use blanks to indicate quantity of devices) <br /> SPRINKLER SYSTEM ENGINE DRIVEN FIRE PUMP <br /> a) Valve Supervisory Switches h) Selector in Auto Position <br /> b)_Building Temperature Points k)_Selector in Auto Position <br /> C) Site Water Temperature Points. i) Engine or Control Panel Trouble <br /> d)_Site Water Supply level Points D Fire Pump Running <br /> ELECTRIC FIRE PUMP ENGINE DRIVEN GENERATOR <br /> e) Fire Pump Power 1) Control Panel Trouble <br /> f)_Fire Pump Running M) Transfer Switches' <br /> g)_Phase Reversal n)_Engine Running <br /> Other Supervisory Function(s)(specify): <br /> 7. Annunciator(s): Qty: Type: Location: <br /> 8. Alarm Notification Appliances and Circuits: <br /> For Emergency Voice/Alarm Service: <br />