My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20355
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20355
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/18/2019 10:51:49 AM
Creation date
3/18/2019 10:51:27 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-20355
Building Department - Name
COIMBRA,GABRIEL & GOMES,RENATA E
Address
6557 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DC RACEWAYS EACH DISCONNECTING MEANS FOR EACH DEVICE WHERE ENERGIZED, LABELING NOTES 1 —98658 <br /> O O SEE NOTE NO.5(DC RACEWAYS) O O UNGROUNDED CIRCUITS MAY BE EXPOSED <br /> PHOTOVOLTAIC EQUIPMENT(JBt,J82,11,12) DURING SERVICE.(JB1,JB2,I1,12) �1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2014 NEC <br /> 1 I <br /> AND 2015 NFPA 1 WILL BE INSTALLED AS REQUIRED. <br /> I WARNING I ,WARN�NtS!I. LABELS,WARNING(S)AND MARKING SHALL COMPLY <br /> JB1-TRANSITION BOX ELECTRIC SHOCKHAZARp.WW TOUCH WITH ANSI Z535.4,WHICH REQUIRES THAT DANGER, <br /> ELECTRIC SHOCK HAZARD:THE DC, <br /> (MODEL NOT SPECIFIED) . ® • ! , ,® + LOAD <br /> SIDE TERMINALS.TERMINALS ON BOTH LINEANDND, ✓,CONDUCTORS OF THIS PHOTOVOLTAIC,SYSTEM, WARNING,AND CAUTION SIGNS USED THE STANDARD <br /> O O LOAD SIDES MAY 8E ENERGIZED IN THE OPEN" , ARE UNGROUNDED BE ENERGIZED. 2 HEADER COLORS,HEADER TEXT,AND SAFETY ALERT <br /> POSITION. SYMBOL ON EACH LABEL.THE ANSI STANDARD <br /> REQUIRES A HEADING THAT IS AT LEAST 50%TALLER <br /> NEC 690.31(G)(3)AND IFC 605.11.1 NEC 690.17(E) NEC 69D.35(F) THAN THE BODY TEXT,IN ACCORDANCE WITH NEC <br /> 110.21(13). LL <br /> J O-TRANSITION BOX OQ OC DISCONNECT I1 12 OS SEE NOTE NO. SW1 O6 AC DISCONNECT SW7 A PERMANENT PLAQUE OR DIRECTORY SHALL BE F- <br /> MDDELNOTSPECIFIED ( ) ( ) ( ) <br /> INSTALLED PROVIDING THE LOCATION OF THE SERVICE (n J <br /> 3 DISCONNECTING MEANS AND THE PHOTOVOLTAIC >- LL m <br /> O O <br /> SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME <br /> LOCATION IN ACCORDANCE WITH NEC 690.56(B). V = m <br /> 11-INVERTER . @ • • RAP" « .. ! WHERE THE INVERTERS ARE REMOTELY LOCATED w LZ z CV) <br /> EDGE SE6000H-US t ®� FROM EACH OTHER,A DIRECTORY IN SHALL BE J <br /> INSTALLED AT EACH DC PHOTOVOLTAIC SYSTEM u- <br /> DISCONNECTING MEANS,AT EACH AC DISCONNECTING O Cn <br /> O2 O3 4O NEcsso.53 NEC 6sass(C)AND IFC605.11.1 NEc6so.54 4 MEANS,AND AT THE MAIN SERVICE DISCONNECTING LLJ o J <br /> MEANS SHOWING THE LOCATION OF ALL AC AND DC J <br /> ANY AC ELECTRICAL PANEL THAT IS FED BY PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IN _ <br /> 12-INVERTER O BOTH THE UTILITY AND THE PHOTOVOLTAIC OB <br /> SOLAR EDGE SE6000H-US AC SOLAR DISCONNECT(SW1) O9 AC DISCONNECT(CBI IN EP1,C821N EP1) THE BUILDING,IN ACCORDANCE WITH NEC 690.4(H). Q <br /> SYSTEM(SWI,EP1,UTILITY METER) 0 m L <br /> LABEL(S)WITH MARKING,"WARNING PHOTOVOLTAIC m LLI ' <br /> POWER SOURCE;SHALL BE LOCATED AT EVERY 10 } <br /> O O�q •, FEET OF EACH DC RACEWAY AND WITHIN ONE FOOT OF J = <br /> I WARNING I . I a 5 EVERY TURN OR BEND AND WITHIN ONE FOOT ABOVE Q Q <br /> DUAL POWER SOURCE,SECOND SOURCE IS '' ' I ' S " AND BELOW ALL PENETRATIONS OF ROOF/CEILING w U � Lu <br /> SW1-DISCONNECT PHOTOVOLTAIC SYSTEM. ` ASSEMBLIES,WALLS AND BARRIERS.THE LABEL SHALL t� N <br /> FATON oG223NR8 HAVE 318°TALL LETTERS AND BE REFLECTIVE WITH <br /> NEC 705.12(D)(3) NEC 690.13(B) NEC690.54 WHITE TEXT ONARED BACKGROUND 0 <br /> OO O O LABELS)WITH MARKING,"PHOTOVOLTAIC SYSTEM <br /> 5 6 7 8 EQUIPPED WITH RAPID SHUTDOWN,"SHALL BE LOCATED <br /> 10 AT POINT-OF-INTERCONNECTION OR AT MAIN SERVICE <br /> AC COMBINER PANEL(EPi) 6 <br /> DISCONNECT THE LABEL SHALL HAVE 318"TALL <br /> EP1-AC COMBINER PANEL LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A <br /> 1 WARNING I <br /> RED BACKGROUND ..:'•,,, <br /> O O 10 <br /> THIS EQUIPMENT FED BY MULTIPLE SOURCES. <br /> TOTAL RATING OF ALL OVERCURRENT DEVICES, <br /> UTILITY METER EXCLUDING MAIN OVERCURRENT DEVICE SHALL <br /> NOT EXCEED AMPACITY OF BUSSAR. <br /> ONEC 705.12(D)(2)(3)(C) <br /> SAFETY LABELS <br /> DOC ID:98658-123961-1 <br /> DATE:1011118 <br /> CREATOR:S.S. <br /> REVIEWER: <br /> REVISIONS <br /> PV-4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.