My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20355
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20355
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/18/2019 10:51:49 AM
Creation date
3/18/2019 10:51:27 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-20355
Building Department - Name
COIMBRA,GABRIEL & GOMES,RENATA E
Address
6557 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIRE SAFETY REQUIREMENTS P-98658 <br /> EXTERIOR-MOUNTED DC CONDUITS,WIRING SYSTEMS, <br /> .� AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL <br /> fh BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, <br /> HIP,OR VALLEY,AND FROM THE HIP OR VALLEY AS <br /> DIRECTLY AS POSSIBLE TO AN OUTSIDE WALL TO <br /> REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION <br /> OPPORTUNITIES NFPA 111.12.2.2.4.1) <br /> -:. ROOF ACCESS POINTS SHALL BE DEFINED AS AREAS <br /> WHERE FIRE DEPARTMENT LADDERS ARE NOT PLACED <br /> OVER OPENINGS(WINDOWS OR DOORS,ARE LOCATED <br /> DIN AT STRONG POINTS OF BUILG CONS11RUCTION,AND LLI 0 <br /> ARE IN LOCATIONS WHERE THEY WILL NOT CONFLICT F- <br /> .'y� - WITH OVERHEAD OBSTRUCTIONS(TREE LIMBS,WIRES, U) J <br /> a OR SIGNS).(NFPA 111.12.2.2.1.3) UJ m 43- <br /> PHOTOVOLTAIC MODULES SHALL BE LOCATED IN A U) U 2 M <br /> MANNER THAT PROVIDES TWO 3 FT WIDE ACCESS O Z () M <br /> 3 PATHWAYS FROM THE EAVE TO THE RIDGE ON EACH w LLJ Z J <br /> •,/�� ROOF SLOPE WHERE THE MODULES ARE LOCATED. 3: 0 LL <br /> �{ <br /> (NFPA 1 11.10.2.2.2.1.2) a <br /> PHOTOVOLTAIC MODULES SHALL BE LOCATED NO LESS d LLI O <br /> THAN 3 FT BELOW THE RIDGE.(NFPA 111.10.2.2.2.2) -3Q S <br /> J <br /> O, ROOF ACCESS POINT,PER NFPA 111.12.2.2.1.3 0 m W <br /> 3.0 FT.WIDE FIRE ACCESS PATHWAY,PER NFPA 1 J = <br /> 11.10.2.2.2.1.2 0 0 �- <br /> O3.0 FT.WIDE SMOKE-VENTILATION SETBACK,PER NFPA F V ti N <br /> 3 111.10.2.2.2.2 I-�' L() <br /> PV MODULES INSTALLED ON ROOF WITH IRONRIDGE �_ Lf) <br /> co <br /> --_=-*- •--w-- ROOF MOUNTING SYSTEM.THE MOUNTING SYSTEM IS <br /> O4 UL 1703 CLASS A FIRE RATED ON A 8112 SLOPED ROOF <br /> 1 FIRE SAFETY PLAN WHEN INSTALLED WITH TYPE 1 OR 2 MODULES.THE 0 <br /> SOLAR WORLD SW 295 MONO IS TYPE 1. <br /> PV-7 SCALE:1'=20' CABLES,WHEN RUN BETWEEN ARRAYS,SHALL BE <br /> 5 ENCLOSED IN CONDUIT. <br /> FIRE SAFETY <br /> PLAN <br /> DOC ID:98658-123961-1 <br /> DATE:1011118 <br /> CREATOR:S.S. <br /> REVIEWER: <br /> REVISIONS <br /> PV-7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.