My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20357
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20357
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/18/2019 10:55:06 AM
Creation date
3/18/2019 10:53:57 AM
Metadata
Fields
Template:
Building Department
Company Name
STAHL FAMILY FARMS LLC
Building Department - Doc Type
Permit
Permit #
18-20357
Building Department - Name
STAHL FAMILY FARMS LLC
Address
40119 COUNTY ROAD 54
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SPECIALTY ELECTRONIC S Y S T E M S y INC. Means of transmission of signals from the protected premises to the central station: <br /> 3791 9 HEATHER PLAZA • DADE CITY, FLORIDA 33525 McCulloh Multiplex One-way radio <br /> 352-567-5996- • 352-52 1 -GOBS p y <br /> OF C SYSTEM <br /> Digital alarm communicator Two-way radio Others <br /> DECOR®OF C <br /> FIRE Means of transmission of alarms to the public fire service communications center: <br /> ,. <br /> _ r <br /> (a) <br /> Name of protected property: <br /> Address: :7 _ `, 2_ Z-C'r•.,,;, 1 i (b) <br /> Representative of protected property(name/phone): System location: <br /> Authority having jurisdiction: r'Address/telephone number: NFPA 72,Chapter 9—Auxillary <br /> Organization n¢me/phone Representative name/phone Indicate type of connection: Local energy Shunt Parallel telephone <br /> Installer Specialty Electronic Systems 352-567-5996 <br /> Location of telephone number for receipt of signals: <br /> Supplier '�;:;^ �� ' '.i a_`-;• : ,-e.,, _� , , .. i <br /> Service organization Specialty Electronic Systems 2.Record of System Installation <br /> Location of record(as-built)drawings: '-*\• (Fill out after installation is complete and wiring is checked for opens,shorts,ground faults,and improper branching, <br /> Location of operation and maintenance manuals: '�`+" but prior to conducting operational acceptance tests.) <br /> Location of test reports: �"'V' <br /> "� This system has been installed in accordance with the NFPA standards as shown below,was inspected by <br /> A contract for test and inspection in accordance with NFPA standard(s) t on ,includes the devices shown <br /> Contract No(s): Effective date: Expiration date: in 5 and 6,and has been in service since <br /> System Software i� NFPA <br /> 72,Chapters-- 1- '2 -3 4 ,5_,.6- .7--8--9 -10---11---(circle-all that apply) <br /> (a)Operating system(executive)software revision level(s): <br /> (b)Site-specific software revision date: <br /> ','NFPA 70,National Electrical Code,Article 760 <br /> (c)Revision completed by: r' <br /> (name) (firm) /fManufacturer's instructions <br /> 1.Type(s)of System or Service _Other(specify): <br /> V�NFPA 72,Chapter 6—Local <br /> If alarm is transmitted to location(s)off premises,list where received: Signed: Date: <br /> Organization: Specialty Electronic Systems <br /> NFPA 72,Chapter 8—Remote Station <br /> Telephone numbers of the organization receiving alarm: 3.Record of System Operation <br /> Alarm: Documentation in accordance with Inspection Testing Form,Figure 10.6.2.3,is attached <br /> Supervisory: All operational features and functions of this system were tested by date <br /> Trouble: and found to be operating properly in accordance with the requirements of: <br /> If alarms are retransmitted to public fire service communications centers or others,indicate location and telephone <br /> numbers of the organization receiving alarm: �%NFPA 72,Chapters 1..._2 =3•$4 '5""6 7 8_ _9_ 10_ .1 _.(dircle all that apply) <br /> Indicate how alarm is retransmitted: <br /> ='NFPA 70,National Electrical Code,Article 760 <br /> NFPA 72,Chapter 8—Proprietary �1Vlanufacturer's instructions <br /> Telephone numbers of the organization receiving alarm: <br /> Alarm: _Other(specify): <br /> Supervisory: <br /> Trouble: Signed: Date: <br /> If alarms are retransmitted to public fire service communications centers or others,indicate location and telephone Specialty ty Electronic Systems <br /> ystems <br /> numbers of the organization receiving alarm: Organization: _ <br /> Indicate how alarm is retransmitted: 4.Signaling Line Circuits <br /> NFPA 72,Chapter 8—Central Station Quantity and class of signaling line circuits connected to system(see NFPA 72,Table 6.6.V: <br /> Prime contractor: V <br /> Central station location: Quantity: Style: Class: ;-`% <br /> (NFPA 72,1 of 4) (NFPA 72,2 of 4) <br />
The URL can be used to link to this page
Your browser does not support the video tag.