Laserfiche WebLink
Encon Services, Inc. <br /> FL EB#9394 1P.O.Box 3613,Apollo Beach,FL,33572 (813)655-3373 <br /> Job Description 1� <br /> Advent Health System <br /> 7050 Gall Blvd. <br /> ZHS-DE 72-IL- LICENSE �y <br /> AHS-DE-72-I L-150 <br /> Florida Building Code,6th Edition(2017) #52949 <br /> ASCE 7-10, Load Case=0.6W+ D <br /> Risk Category II 1 STATE OF <br /> �O <br /> Exposure C �o,�FS�ORIIDAG <br /> Kd 0.85 SOON �N <br /> Kz 0.85 <br /> VULT(MPH) 150 Aaron Biedenbach, P.E.#52949 <br /> VASD(MPH) 116 Date Signed: 9/26/2018 <br /> Cf 1.50 <br /> G 0.85 Wind Pressure(ULT) <br /> 1 53 PSF <br /> Sign Area Distance to Center P=Force Moment <br /> sf ft (lb) ft-lb <br /> Can 1 24.60 4.13 781 3225 <br /> Totals 781 3,225 <br /> Required Flexural Strength (kip-ft) 3.22 <br /> Provided Flexural Strength (kip-ft) 3.82 3.50"O.D. (.216 wall)Grade A53 B Steel'Pipe <br /> 0.843494 <br /> Auger Foundation Design Per Support <br /> Diagonal B(FT) 2.00 Base Size Required <br /> Lateral soil pressure(LB/SF/FT) 150 4.5 FT Deep <br /> Depth(Estimated)(FT) 4.5 2.0 FT Diameter <br /> S1 450 or <br /> Design Depth(FT) 4.20 Ft 2.5 FT Square <br /> 3.5 FT Deep <br /> Anchor Bolt and Base Plate Design Per Support <br /> Distance Between Bolts 4.6 4206 Tension on Bolts(LB) <br /> Number of Bolts per Base Plate 4 Use 3/4"Dia. F1554 Gr36 Bolts <br /> Plate Width B(IN) 4.6 0.47 Plate thickness(IN) <br /> Bolt Spacing d(IN) 4.6 Use 1"A36 Plate <br /> Width of Pole-(IN) 3.5 <br /> Combined <br /> Circular Weld Stress <br /> Diameter thickness <br /> 3.5 0.375 16.78 OK <br /> 9/26/2018 <br /> Advent Health Zephyrhills AH5 DE 72 IL 150 5tandard <br />