Laserfiche WebLink
Encon Services, Inc. <br /> Sign Design Calculations. <br /> Job Description PREPARED BY: Encon Services, Inc. <br /> Advent Health P.O. Box 3613 <br /> 7050 Gall Blvd. Apollo Beach, FL 33572 <br /> Zephyrhills, FL 813-655-3373 <br /> AHS-30-STK F 813-655-9814 <br /> Design per Florida Building Code,6th Edition(2017)Section 16 Wind Load <br /> ASCE 7-10, Load Case: D+0.6W Aaron Biedenbach, P.E. <br /> Design Specifications FL PE#52949, FL EB 9394 <br /> Risk Category II OH PE 60756, OC#01893 <br /> Kzt 1 KY PE #20281, P#2463 <br /> Exposure Factor C IN PE#PE 19600332 <br /> Kd 0.85 FL CBC#060535,QB#22527 <br /> Kz <br /> .09 <br /> V 1150 (mph) O_`Q• BI,E <br /> GCp=GCpi 1.1 Zone-4, H<60 Feet <br /> Wind Pressure 58.7 (psf) �' LICENSE �y <br /> #52949 <br /> Sign Information <br /> Height 2.50 (ft) STATE OF <br /> Width 11.50 (ft) A �. <br /> Thickness 1.00 (ft) ���. �0R?JQQ` <br /> Distance grade to top 50 (ft) <br /> FS's+�o �NG <br /> Wind Shear Force 88.05 (lb) <br /> Weight of Sign 288 (lb) DATE SIGNED: <br /> Total Shear Force = 300.68 (lb) 9/26/2018 <br /> Total Tension Force = 1012.63 (lb) <br /> Required Provided <br /> Fastener size(Nominal) 3/8 3/8 <br /> Minimum number of fasteners 6 6 <br /> Shear Force per fastener(lb) 50.1 280 <br /> Tension Force-per fastener(lb) 168.8 352 <br /> Combination Tension and 0.66 <1 O.K. <br /> Sheer-ratio <br /> THREADED ROD THROUGH WALL IS PREFERRED IN ALL INSTANCES. IF IT IS NOT POSSIBLE TO USE THREADED ROD,SEE CHART BELOW <br /> FOR APPROPRIATE ANCHOR SELECTION.SIZE AND NUMBER REQUIRED ARE NOTED IN THE CHART ABOVE. <br /> WALL STRUCTURE ANCHOR TYPE <br /> WOOD BLOCKING LAG BOLT(3"EMBEDMENT)THROUGH BLOCKING <br /> EIFS OVER 5/8'PLYWOOD LIBERTY TOGGLE BOLT OR THRU BOLT WITH SLEEVE <br /> HOLLOW CONCRETE BLOCK,BRICK SLEEVE ANCHOR(1-112°EMBEDMENT) <br /> SOLID CONCRETE WEDGE ANCHOR(2-1/T EMBEDMENT) <br /> CMU,SOLID CONCRETE,BRICK IHILTI HIT ROD W/HY-20 ADHESIVE(31/T EMBEDMENT) <br /> ALL ANCHORS SHALL BE CHOSEN AND PLACED IN ACCORDANCE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS <br /> 9/2 612 0 1 8 <br /> Advent Health Zephyrhills 32277-AHS-30-STK C <br />