Fields
Template:
Building Department
Company Name
COLONY HEIGHTS
Building Department - Doc Type
Permit
Permit #
18-20420
Building Department - Name
PALAZZI,THOMAS & CATHERINE
Address
39050 12TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIRE SAFETY REQUIREMENTS P-100054 <br /> N EXTERIOR-MOUNTED DC CONDUITS,WIRING SYSTEMS, <br /> AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL <br /> BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, <br /> HIP,OR VALLEY,AND FROM THE HIP OR VALLEY AS <br /> DIRECTLY AS POSSIBLE TO AN OUTSIDE WALL TO <br /> REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION <br /> OPPORTUNITIES(NFPA 111.12.2.2.4.1) <br /> ROOF ACCESS POINTS SHALL BE DEFINED AS AREAS <br /> WHERE FIRE DEPARTMENT LADDERS ARE NOT PLACED <br /> OVER OPENINGS(WINDOWS OR DOORS),ARE LOCATED <br /> AT STRONG POINTS OF BUILDING CONSTRUCTION,AND W <br /> 1 ARE IN LOCATIONS WHERE THEY WILL NOT CONFLICT (— <br /> WITH OVERHEAD OBSTRUCTIONS(TREE LIMBS,WIRES, (n N <br /> OR SIGNS).(NFPA 1 11.12.2.2.1.3) >- �. <br /> PHOTOVOLTAIC MODULES SHALL BE LOCATED NO U co."„.,I Icy;I I•�i ,, I ',,,�.,I �� CLOSER THAN 1-1/2 FEET TO A HIP OR VALLEY IF Of Z W <br /> MODULES ARE TO BE PLACED ON BOTH SIDES OF THE Lu <br /> HIP OR VALLEY.WHERE MODULES ARE LOCATED ON W Q J <br /> ' ONLY ONE SIDE OF A HIP OR VALLEY OF EQUAL LENGTH, LL <br /> THE PHOTOVOLTAIC MODULES SHALL BE ALLOWED TO O 7U7BE PLACED DIRECTLY _ <br /> VALLEY.(NFPA 111.10.2.22.1.9)T TO THE HIP OR <br /> PHOTOVOLTAIC MODULES SHALL BE LOCATED NO LESS Q p = <br /> i; � 4 THAN 3 FT BELOW THE RIDGE.NFPA 111.10.2.2.2.2) J N <br /> (f) Q M <br /> PV MODULES INSTALLED ON ROOF WITH IRONRIDGE 0 Q a. <br /> ROOF MOUNTING SYSTEM.THE MOUNTING SYSTEM IS W d W <br /> O UL 1703 CLASS A FIRE RATED ON A 8/12 SLOPED ROOF <br /> ''�'; - �'`•'" "1••1• +.;<-�`" WHEN INSTALLED WITH TYPE 1 OR 2 MODULES.THE N <br /> SOLAR WORLD SW 295 MONO IS TYPE 1. � <br /> O2 ROOF ACCESS POINT,PER NFPA 111.12.2.2.1.3 EE <br /> 1 FIRE SAFETY PLAN O 3.0 FT.WIDE FIRE ACCESS PATHWAY,PER NFPA 1 U <br /> PV-7 SCALE:1"=20' 3 11.10.2.2.2.1.3 AND NFPA 111.10.2.2.2.1.2 <br /> O ROOF ACCESS POINT,PER NFPA 111.12.2.2.1.3 <br /> 5 CABLES,WHEN RUN BETWEEN ARRAYS,SHALL BE <br /> ENCLOSED IN CONDUIT. <br /> FIRE SAFETY <br /> PLAN <br /> DOG ID:100054-125660-1 <br /> DATE:10/18/18 <br /> CREATOR:S.S. <br /> REVIEWER: <br /> REVISIONS <br /> PV-7 <br />