Laserfiche WebLink
T (1 <br /> FORM R405-2017 <br /> FLORIDA ENERGY. EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and.Professional Regulation - Residential Performance Method �• <br /> Project Name: Zook "��� � Builder Name:J�Di WK <br /> Street: 5-bc5-0 t 5 7' ..`7 yeU� S Permit Office: Pasco <br /> City,State,Zip: FL, Permit Number: I ig 6 59 <br /> Owner: Zook Residence Jurisdiction: G 1((0 dt) <br /> Design Location: . -FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1468.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insui,Exterior R=5.0 1278.00 W <br /> b.Frame-Wood,Exterior R=11.0 180.00 ft' <br /> 3. Number of units,if multiple family 1 c.NIA R= ft' <br /> 4. Number of Bedrooms 3 d.N/A R= ft' <br /> 5. Is this a worst case? No 10.Ceiling Types(1410.0 sgft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1410.00 ft' <br /> 6. Conditioned floor area above grade(ft') 1410 b.N/A R= ft' <br /> Conditioned floor area below grade(ft') 0 R= ft' <br /> 11.Duct <br /> s R ft' <br /> 7. Windows(96:0 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 200 <br /> a. U-Factor: Dbi,U=0.35 96.00 ft' <br /> SHGC: SHGC=0.25 <br /> b. U-Factor: N/A ft' 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ft' <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: NIA ft' a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.000 ft. <br /> Area Weighted Average SHGC: 0.250 14.Hot water.systems <br /> 8. Floor Typ a.Electric Cap:40 gallonses (1410.0 sgft.} Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1410.00 ft' b. Conservation features <br /> b.N/A R= ft' None <br /> c.NIA R= ft' 15.Credits Pstat <br /> Glass/Floor Area: 0.068 Total Proposed Modified Loads: 45.42 PASS <br /> S <br /> Total Baseline Loads: 47.65 J'1 �7 <br /> I hereby certify that the plans and specifications covered by Review of the plans and Q,�"ilfgZ".gr� <br /> this calculation are in compliance with the Florida Energy specifications covered by this ' .: ., "dot+ ` <br /> Code. calculation indicates compliance <br /> � ��2itd- with the Florida Energy Code. ir+ lirrir. < .•s - .`�� <br /> PREPARED BY: Before construction is completed, - <br /> DATE: 1 �-- this building will be inspected for <br /> compliance with Section 553.908 #. <br /> I hereby certify that this building,as designed,is in compliance Florida Statutes. , <br /> with the Florida Energy Code. b!W's"l'��, <br /> OWNER/AGENT. BUILDING QFFI AL: <br /> DATE: DATE: <br /> Compliance requires certification by the air handier unit manufacturer that the air handler.enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 4.50 ACH50(114024.1:2).. <br /> - Compliance with a'proposed duct leakage Qn requires a Duct Leakage Test Report Confirming duct leakage to outdoors, <br /> tested In accordance with ANSNRESNETACC 380,Is not greater than 0.030 Qn for whole house. <br /> i <br /> i <br /> 1/5/201811:56 AM EnergyGauge@ USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1.of 4 <br /> � I . <br />