My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19443
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19443
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2019 9:33:05 AM
Creation date
5/23/2019 9:33:04 AM
Metadata
Fields
Template:
Building Department
Company Name
OAK PARK
Building Department - Doc Type
Permit
Permit #
18-19443
Building Department - Name
HARTSOCK,BARRY
Address
38515 NAOMIA AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. 07/16/2015 10:05 7278634273 ABC SUPPLY CO ING , PAGE 02/04 <br /> i <br /> FL 7271.11-1t3 <br /> C1999-19 <br /> 3.20.15 <br /> Page 2 of 3 <br /> Manufacturer: Union Conugating Company � <br /> Product Name: MasterRib Panel <br /> Panel Description:- 36"wide coverage with 3/4"high ribs at 9"o.c. <br /> Materials: Minwawna 29 ga., 80 ksi steel. Csalvanized coated steel(ASTM A653) <br /> or Galvalume coated steel (ASTM A792) or painted steel (ASTM <br /> A755). <br /> Support Description: Note. 1" x 4" ( ) luuaber at max. 24" o.c. (Must be designed by <br /> others) <br /> Support Attachment: (1)49 x 3"long wood screw into rafters spaced at max 24"o.c. <br /> New Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1. <br /> Required for new construction and optional for reroofing construction. <br /> Existing Underlayment: One layer of asphalt shingles over one layer of 930 felt.For xexoofing <br /> (Optional) construction only. <br /> Deck Description: Min 7/16"thick OSE deck or min. 15/32"thick APA rated plywood or <br /> min. 3/4' thick wood plank (min SG of 0.42) for new and existing i <br /> constructions.Designed by others and installed as per FBC 2014. <br /> SIope: 1/2:12 or greater in accordance with FBC 2014 Section 1507.4.2 <br /> Design Uplift Pressure: 71 psf for Fastener Pattern 1 <br /> (Factor of Safety=2) 114 psf for Fastener Pattern 2 <br /> Panel Attachment: #9-15 or 910-14 wood screw with washer. Fastener shall be of <br /> sufficient length to penetrate through the support and deck a mum <br /> of 3/8". <br /> Fattem 1 @ 9"o.c.across panel width <br /> Pattern 2 @ 5.5"-3.5"-5.S"o.c.across panel width <br /> Sidelap Attachment: 1/0-14 x 7/8" long SDS with washer@ 24" o.c. Recommended for <br /> (Optional) roof slope less than 3:12. <br /> Test Standards: Panel assembly tested in accordance with ASTM E1592-01 `Test <br /> Method for Structural Performance of Sheet Metal Roof and Siding <br /> Systems by Uniform Static Air-Pxessnre Difference' and FM 4470 � <br /> Section 5.5 `Resistance to Foot Traffic'. <br /> Code Compliance: The product described herein has demonstrated compliance with FBC <br /> 2014 Section 1507.4 <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.