Laserfiche WebLink
FORM R405=2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 520317TH ST Builder Name: Michael L Baxter Air Conditioning Inc <br /> Street: 5203 17th Street Permit Office: '. ��" epkq�u l� <br /> City,State,Zip: Zephyrhills,FL,33542 Permit Number. <br /> Owner. Kerns Family Construction Jurisdiction: (4 t t(91)a <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1687.5 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=6.0 1687.50 ft2 <br /> b.N/A R= ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 3 d.N/A R= ft2 <br /> 10.Ceiling Types (1442.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 1442.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1442 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(92.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 575 <br /> a. U-Factor. Dbl,U=0.40 92.00 ft2 <br /> SHGC: SHGC=0.25 <br /> b. U-Factor: N/A ft2 12.Cooling systems kBtulhr Efficiency <br /> SHGC: a.Central Unit 34.4 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor. WA ft2 a.Electric Heat Pump 34.4 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.000 ft. <br /> Area Weighted Average SHGC: 0.250 14.Hot water systems <br /> 8. Floor Types (1442.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF:0.920 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1442.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits CF,Pstat <br /> Glass/Floor Area: 0.064 Total Proposed Modified Loads: 54.05 PASS <br /> Total Baseline Loads: 55.43 <br /> 1 hereby certify that the plans and specifications covered by Review of the plans and �Z$E ST,q?, <br /> this calculation are in compliance with the Florida Energy specifications covered by this _4V _ 0 V% <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. ti ++++,,�:'� :_ •;;.,''��,� <br /> PREPARED BY: 'JA!Z Before construction is completed <br /> DATE: �G ` / J this building will be inspected for 0 <br /> compliance with Section 553.908 <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. 1 �� <br /> with the Florida Energy Cp e. COD WE <br /> OWNER/AGENT: V BUILDING OFFICIAL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 4.54 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.000 Qn for whole house. <br /> 9/19/2018 10:26 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 5 <br />