Laserfiche WebLink
R R W Building Consultants, Inc. <br /> W ? <br /> D Consulting and Engineering Services for the Building Industry ' <br /> D C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 <br /> FloridaBoard of Professional Engineers Certificate orAuthorization No.9313 <br /> Produet EVAIiiA011 / I I / l <br /> l I <br /> Product Sub Category Manufacturer Product Name <br /> Category <br /> Wincore Window Company,LLC, 7700/9900 Series <br /> Windows Horizontal Slider 250 Staunton Turnpike Vinyl Horizontal Sliding Window <br /> Parkersburg,WV 26104 "Non-Impact" <br /> Scope: This is a Product Evaluation report issued by R W Building Consultants,Inc.and Lyndon F.Schmidt,P.E.(System ID# <br /> 1998)for Wincore Window Company,LLC.based on Rule Chapter No.61G20-3,Method I of the State of Florida Product <br /> Approval,Department of Business&Professional Regulation. I <br /> RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company <br /> manufacturing or distributing the product or In any other entity involved In the approval process of the product named <br /> herein. <br /> Limitations; <br /> 1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)structural requirements <br /> excluding the"High Velocity Hurricane Zone"(HVHZ). <br /> 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing <br /> or stucco. i( <br /> .3. When used In areas requiring wind borne debris protection this product is required to be protected with an impact resistant covering <br /> that complies with FBC Sections 1609.1.2&R301.2.1.2. <br /> 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. <br /> 5. Site conditions that deviate from the details of drawing FL-16092.10 require further engineering ana►ysis by a licensed engineer or <br /> registered architect. <br /> 6. See drawing FL-16092.10 for size and design pressure limitations. <br /> Supporting Documents: <br /> 1. Test Report No. Test Standard Testing Laboratory Signed by <br /> ATI C7083.02-50147 AAMAIWDMA/101/I.8.2/A440-08 Architectural Testing,Inc. Lynn George <br /> 2. Drawing No. Prepared by Signed&Sealed by <br /> No.FL-16092.10 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> 3. Calculations Prepared by Sinned&Sealed by <br /> Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> 4. Quality Assurance <br /> Certificate of Participation Issued.by National Accreditation and Management Institute,certifying.that Wincore Window <br /> Company,LLC.Is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and <br /> Guide 53. <br /> cHkil <br /> 1 <br /> I <br /> i <br /> yh�;7ez..i09rr <br /> r� <br /> TAT E OF �•,l; <br /> . a�`'S/piiseaa�4e�os � <br /> Lyndon F.Schmidt,P.E. <br /> FL PE No.43409 <br /> 7/20/2017 <br /> Sheet 1 of 1 <br /> I <br />