Laserfiche WebLink
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Galen 2432 Elev D Builder Name: D H Express Hoknes <br /> Street: L/ Permit Office: C"Yy'up&,,�Wts <br /> City,State,Zip: Zephyrhills,FL, _5q Permit Number: 1 W I Z' <br /> Owner: Jurisdiction: & 1(&00 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2 <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2511.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=1 1.0 1269.30 ft2 <br /> b.Concrete Block-Int Insul,Exterior R=4.1 956.22 ft2 <br /> 3. Number of units,if multiple fa I mily 1 c.Frame-Wood,Adjacent R=1 1.0 286.00 ft2 <br /> 4. Number of-Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? No 10.Ceiling Types (1451.0 sqft.) Insulation - Area <br /> a.Under Attic(Vented) R=30.0 1451.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 2432 b.N/A R= ft2 <br /> N/A <br /> Conditioned floor area below grade(ft2) 0 C.11.Duct R= ft2 <br /> s R ft2 <br /> 7. Windows(229.0 sqft,) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 231 <br /> a. U-Factor: Dbl,U=0.34 189.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: DIJI,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 33.8 SEER:14.00 <br /> c. U-Factor: - N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 33.8 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.585 ft. <br /> Area Weighted Average SHGC: 0.315 14.Hot water systems <br /> 8. Floor Types (1451.0 sqft.) Insulation Area a.Electric Cap:50 gallons <br /> a.Slab-On-Grade Edge Insulation R=O.O 1019.00 ft2 b. Conservation features EF:0.950 <br /> b.Floor over Garage R=19.0 432.00 ft2 None - <br /> c.N/A - R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.094 Total Proposed Modified Loads: 74.13 PASS <br /> Total Baseline Loads: 74.48 <br /> I hereby certify that the plans and specifications covered by Review of the plans and '0*V14E S7, <br /> this calculation are in compliance with the Florida Energy specifications covered by this 0 <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY: Before construction is completed <br /> DATE: 17 this building will be inspected for _,,I <br /> compliance with Section 553.908 <br /> .1 hereby certify that this building,as designed,is in compliance Florida Statutes. <br /> with the Florida Energy Code. <br /> OWNER/AGENT• BUILDING OFFICIAL: 1111�7/0- <br /> DATE:. ore-III I DATE: <br /> - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESINIET Standards,Is not greater than 0.060 On for whole house. <br /> 11/8/2017 4:41 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />