. , : Sing e ami y. we ing <br /> P lan Review Comments <br /> l: F.F.E. shall be a minimum of 8"_above.the road.elevation:and an engineered.site_plan. <br /> . . <br /> 2. Lots shall be graded to,comply with R401.3 of the F.R.C. .: <br /> 3.: ,Compaction test required if'24" or more:of fill-dirt is.brought in:at any one place: <br /> 4. .Tie in.survey required before pouring concrete.. <br /> 5.. -Driveways:require a-R.O.W. use permit: All 4sides of driveway thru the sidewalk shall have <br /> expansion material:. :. . „ <br /> 6.. .All setbacks.shall be met.. <br /> 7.: ;All.property.markers shall be.uncovered:and marked at time of first inspection: <br /> .8'. A11 A:D.A:requirements shall be met.: . <br /> 9. No electric,plumbing,.mechanical;.or framing shall be covered without an:inspection and _ <br /> approval first. <br /> 10. All.Garages shall comply:with:section R302.6_of the F.B.C.: (Fire S:eparation). <br /> . 11. Appliances shall:not installed in:a�location where siibjectto.mechanical damage unless <br /> pfotected:'by approved barriers. M303.4 of.the F.B:C. <br /> 12. Water_heaters shall comply.with section:P667.3 of the F.R.C: <br /> 13. Foundation supports for.A/C.units shall be raised at least 3'.' above finished gr de.. M1308.1. <br /> 14. Return air in all,bedrooihs.,F.B.C. .Ml620,4 <br /> 15.;Smoke detectors are.to be installed.in accordance4ith:R313:.1 of the.F.B.C. <br /> :.16. All glazing requirements are:.to be in accordance with R308.4_of the.F.B.C. <br /> 17. All means,of egress are to be in accordance with R31 Lof the F:B.C.. <br /> 18. `.`Green gypsum.board" shall-not be used:as.a backer in showers:or tubs. R702.4.2-F.B.C: <br /> . 19. Combination-type AFCI breakers.are required;at all.locations requiring_an AFCI_type breaker: <br /> 20. Carbon monoxide.alarms:will be required in new:construction that uses fossil-burning heating <br /> :or appliances or an attached garage:_ They shall be installed in accordance with.the F.B.C. <br /> 21. All plumbing, mechanical,:and:electrical shall be separate from unit to:unit: This includes all. <br /> underground plumbingand electric: <br /> 22. All 2016:N:E:C: Codes:will be enforced:. <br /> 23:Tamper=Resistant Receptacles in accordance with 06.11-of the 2016 N.E:C <br /> 24::Iri accordance.With the Land:Development:Code,lots shall be sodded before final at least 10 <br /> feet around..the structure. <br /> 25. Blower door:test and blown in insulation-card shall be provided before C:.O: <br /> -26 A copy ofthe energy cads shall be with pernzit-at.all times. <br /> 2T.-Copy of final insulation report shall be:provided:avitlz.periiiit befoie rinaL <br /> F.F.E.-Finished Floor Elevation <br /> F.B.0 Florida'Building Code 6t'Edition. <br /> R.O.W.-Right of-Way :. <br /> A.D.A.-Americans with.Disabilities Act N.E.C.-National Electric Code(2011.) <br />