Laserfiche WebLink
Manual S Compliance Report Job: <br /> - - wrightsoW p p Date: Oct 07,2014 <br /> Entire House By: <br /> Progressive Air Systems, Inc <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> Project • • <br /> For: DR Horton/Express <br /> Lot 19 Blk 6 Silverado, Zephyrhills, FL <br /> 'Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.2°F Sensible gain: 24265 Btuh Entering coil DB: 76.0°F <br /> Outdoor design WB: 77.1 OF Latent gain: 3250 Btuh Entering coil WB: 63.0°F <br /> Indoor design DB: 75.0°F Total gain: 27515 Btuh <br /> Indoor RH: 50% Estimated airflow: 1120 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB036****A+FB4CNP036 <br /> Actual airflow: 1120 cfm <br /> Sensible capacity: 26365 Btuh 109%of load <br /> Latent capacity: 4753 Btuh 1460%of load <br /> Total capacity: 31118 Btuh 113%of load SHR: 85% <br /> fleating 'Equipmont'. <br /> Design Conditions <br /> .Outdoor design DB: 40.0°F Heat loss: 22889 Btuh Entering coil DB: 69.5°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer:. Carrier Model: CH14NB036****A+FB4CNP036 <br /> Actual airflow: 1120 cfm <br /> Output capacity: 30307 Btuh 132%of load Capacity balance: 30 OF <br /> Supplemental heat required: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1120 cfm <br /> Output capacity: 7.5 kW 1120%of load Temp. rise: 17 OF <br /> Meets are all requirements of ACCA Manual S. <br /> _LLLwri htsofts 2017-Nov-0910:54:09 <br /> 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 <br /> ...les\Express homes\Galen 4EGB-3 ton New Code.rup Calc=MJ8 House faces:NW <br />