Laserfiche WebLink
Project Summary Job: <br /> - wrightsofto Date: Oct 07,2014 <br /> Entire House By: <br /> Progressive Air Systems, Inc <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> •,*ect In"ormation <br /> For: DR Horton/Express <br /> Lot 19 Blk 6 Silverado, Zephyrhills, FL <br /> Notes: <br /> Design Information <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 40 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 30 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 18093 Btuh Structure 18452 Btuh <br /> Ducts 4796 Btuh Ducts 5812 Btuh <br /> Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification - 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 22889 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 24265 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2371 Btuh <br /> Ducts 880 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2) 2478 2478 Equipment latent load 3250 Btuh <br /> Volume(ft3) 20539 20539 <br /> Air changes/hour 0.22 0.11 Equipment total load 27515 Btuh <br /> Equiv.AVF(cfm) 75 38 Req. total capacity at 0.75 SHR 2.7 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model CH14NB036****A Cond CH14NB036****A <br /> AHRI ref Coil FB4CNP036 <br /> AHRI ref <br /> Efficiency 8 HSPF Efficiency 11.7 EER, 14 SEER <br /> Heating input Sensible cooling 25200 Btuh <br /> Heating output 34000 Btuh @ 470F Latent cooling 8400 Btuh <br /> Temperature rise 28. OF Total cooling 33600 Btuh <br /> Actual air flow 1120 cfm Actual air flow 1120 cfm <br /> Air flow factor. 0.049 cfm/Btuh Air flow factor _ 0.046 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.88 <br /> Capacity balance point=30 OF <br /> Backup: <br /> Input=8 kW, Output= 25681 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> ^� Wrlg htsoft" 2017-Nov-0910:54:09 <br /> AC� Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 <br /> ...les\Express homes\Galen 4EGB-3 ton New Code.rup Cale=MJ8 House faces:NW <br />