Single Family Dwelling. <br /> Plan Review.Comments <br /> I- F.F.E. shall be a minimum of 8- above.the road elevation and ari engineered site plan. <br /> 2. Lots shall be graded to,comply with R401.3 of the F.R.C. <br /> 3. ;Compaction lest required if 24" or more.of fill dirt is brought_in-at any one place: . <br /> 4: Tie in survey required before pouring concrete.. . <br /> 5.' Driveways require a R:O.W. use permit: All sides of.driveway thra the sidewalk shall have. <br /> expansion matenal: <br /> 6.. All.setbacks shall,be met.: <br /> 7. All.property:markers shall be 'uncovered and marked at time of first 'inspection. <br /> 8.- All A.D.A. requirements shall be met.: . <br /> 9. .No:electric;plumbing, mechanical, or-frainirig shall be covered without an:inspection and <br /> approval first. . . <br /> 10. All Garages shall:comply_-with section R302:6.of the F.B.C. (Fire Separation). <br /> 11. Appliances.shall�not.be installed in.a locationwhere subjectto,mechanical damage unless <br /> :protected by approved barriers: M303.4 ofthe F.B:C <br /> 12. Water heaters shall corriply.with section.P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C.units.shall be raised at least 37 above finished grade. M1309.1 <br /> 14. Return air in all:bedrooms..F:B.C. M..1620.4 <br /> 15. Smoke detectors'are to be installed:in accordance with.R313.1 -of the:F.B.C. <br /> 16..All glazing requirements are:.to be in accordance'with R308.4-of the F.B.C.- <br /> 17. All means,of egress are to:be in.accordance with R311:of the RB.C. <br /> 18. `.`Green gypsum board" shall not be used:as.a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19.-Combination-type-AFCI breakers are required.at all locations requiring.an AM type breaker: <br /> 20. Carbon monoxide.alarms will-be required in new construction that uses fossil-burning heating <br /> :or appliances or an attached garage: They shall be.installed in accordance with,the F.R.C. . <br /> 21. A1l plumbing,mechanical,'and electrical shall:be separate from unit to:unit: This includes all <br /> under ourid lurnbin gr p g and electric: <br /> 22, All 2016:N-.E.C; Codes will'be enforced..'. <br /> 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E:C <br /> .24. In accordance:.with.the Land.Development:Code, lots.shall be sodded before final at least-I0. <br /> feet around:the structure. <br /> 25. Blower door test and blown in insulation card shall be provided before C..O: <br /> 26.-A copy ofthe energy ea Is shall be with permit.at all times <br /> 27. Copy of final insulation report shall be:provided with:permit before fnal. . <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6�' Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2011) <br />