Laserfiche WebLink
� Y Lbw llirz g . . <br /> din 1e. Famil . <br /> Mari Review Comments <br /> - . . I.. .F.F.E,shall be a minimum of$ ? above the.Toad*elevation.and_an.eh6neeredsite plan: <br /> 2: Lots,shall.be graded to comply.with:R401:3 .of the F;B.-C: <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at.any one:place: - <br /> 4: Tie in survey required before,pouring concrete.` <br /> 5..:Driveways require:a R.O W:use perinit::AlIA:sides of driveway thru the sidewalk-shall have ; <br /> expansion material. .: <br /> 6. All setbacks shall be met': <br /> ' 7.. .All ro ert inarkers shallbe.uncovered and marked at time:of first ins ection:. <br /> p. p. .Y. inspection. <br /> 8: All-A.:D.A:requirements-shall be:"'et. <br /> 9: : No.electric;,plumbing; mechanical;.or framing a -all be covered"withouf.an inspection and <br /> .: .approval first. <br /> . <br /> - 10.- All-Garages:shall comply with section.R302.6 of the.F.B.C:-(Fire Separation):.: <br /> Appliances shall riot b.e installed-in-a location where:subject to mechanical dainage:unless : <br /> pyrotected b a pp roved barriers. M303.4 of the F.B.0 <br /> : <br /> 12::Water heaters shall-comply with_section P607.3.of the_F.B.C. <br /> I3:.:Fouriilatibn supports..for A/ units shall:be raised.at least.3" above finished grade: IWI l30$:1 <br /> 14. Return air.in all.bedrooms.-F.B.C. ML620..4 <br /> 15:.Smoke detectors are to be-installed in-accordance with R313.1 ofthe F.B:C,.. <br /> 16.All glazing requirements.are to be in,accordance.with R3.08.4.-of the F.B.C. <br /> 17.;All.rrieans of egress are..tb be in accordance with R31 l:of the:F.B.C. .: <br /> 18. ``Green » <br /> gypsum board sliall.not be'used as a backer'in showers or ttibs.:R702:4.2.F.B.C. : :: <br /> 19. Combination-type AFCI breakers.Are'required at all locations requiring an AFCI'type breaker. <br /> 20: Carbon monoxide alarnis:will be required in-zxew coistruetion that uses fossil=burning jieatng:-: <br /> -. <br /> or appliances or an:attached garage. They shall:h&installed in:accordance with the F:B:C. <br /> 2 L A11_plumbing;mechanical and electrical shall be-separate from unit to unit. This includes all <br /> underground plumbing.and electric: . -- <br /> : : 22.- All 2011.N.E:C. Codes will bee' <br /> nforced: <br /> 23.Tam_per Resistant Receptacles in accordance with 406.11 of the 20a.1 N.E. <br /> .. <br /> 24:.In accordance with the Land Developmerit Code,-lots-shall be.sodded before final.'at.Ieast:10 <br /> feet around the:structure.. <br /> 25. Blower.door.test.8hall:be provided before C.CO: <br /> 2.6.:. -copy�f the crier cads es be 4vitii peeatit kt all tirites <br /> 27'Copy bf Linal insidation report �laall be tea'®viiled with.�errorit before final <br /> _ <br /> F.F.E.-Finished Floof Elevation <br /> F.B.C-.Florida Buildirig.Code6�'Edition <br /> K O.W:-Right-of Way <br /> XD:A-Americans with Disabilities Act N.E.C.-National Electric ode <br /> on - ::: <br />