Laserfiche WebLink
ellSin leFamil g in <br /> g <br /> Plan Review Comments.1: F.F.E. shall be:a minirnum:of 8 above.-the road,elevation and an engineered site plan. <br /> I Lots shall be graded.to.comply withR401.3 of the F.B.C: .: <br /> 3.: Compaction:test required.if 24" or more:of,-f ll dirt is.brought in:at any one place: <br /> .4:. :Tie in.survey required before pouring concrete. <br /> 5.:_ Driveways:require a R.O.:W. use permit:: All 4:sides of driveway.thru the sidewalk shall-Have. <br /> expansion material. <br /> 6._ All setbacks shall be met:. <br /> .7. All.property:markers shall be uncovered and marked.at time of first.'inspection: <br /> .8:. All A.D.A. requirements shall be met. . <br /> 9.: No:electric;plumbing,_mechanical;.or framing shall be covered without an;inspection and <br /> approval first. <br /> M All Garages shall_comply:.with.section R302;6:of the F.B.C:-(Fire Sbparation).. <br /> 11:Appliances=shall not be installed in a location where subject to:rriechariical damage unless <br /> protected:by approved barriers. M303A of the F.B:C- <br /> 12. Water heaters shall comply:with section:P607.30.f the F.R.C. <br /> 13. Foundation supports for.A/C units.shall'be raised at least 3"above finished-grade. M1308,1. - <br /> 14. Return air in all bedrooms.:F.B.C. M1620.4- <br /> 15: Smoke detectors are to be in'stalled-in accordance:with:R31.3.1 of theT.B_.C. -: <br /> : .16::All glazing requirements are..to be in accordance with R308.4,of the F.B.C. . <br /> 17.All means of egress are d.be- in-accordance with R31 Lof the F:B.C. .. : . <br /> 18. ." gyp Green sum board,� .shall not be used:as a backer:in:showers:or tubs. R702.42 F.B.C.- <br /> . . <br /> 19..'Combination-type AFCI breakers are.required.af all,locations requiring:an AFCLtype breaker: <br /> 20:.Carbon monoxide alarms will be required in.'new:construction that uses_fossil-burning heating <br /> :or appliances or an attached garage. They shall be.installed in accordance with the P.B.C.. <br /> :..21.All plumbing, mechanical,:and electrical shall:be separate from unit to.unit: This includes all. - <br /> underground plumbing-arid electric: <br /> _ . <br /> 22.. All 2016.N.E:C. Codes will.be enforced.. <br /> 23: Tamper-Resistant Receptacles in accordance with 406.11 of-the 2016 N.E:C :- - <br /> . . <br /> .24::Iii accordance:.with the Land.Development.Code, lots shall be sodded before final of lea_st 10 <br /> feet around:the structure._ - <br /> 25. Blower door:test and blown iri.insulation card shall be provided before C:.O: <br /> 26-A copy ofthe MerjE cdcls.shall be with permit.at all times. <br /> 27."-Copy of final insulation report shall be:provided-with:permit before:final <br /> F.F:E.-Finished Floor Elevation <br /> F B.C=Florida Building Code 6f'Edition- <br /> R.O:W:-Right:ofWay <br /> A:D.A:-Americans with.Disabilities-Act N.E.C.-.National Electric Code(2011.) <br />