My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19984
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19984
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2019 11:12:44 AM
Creation date
5/23/2019 11:12:43 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19984
Building Department - Name
LENNAR HOMES LLC
Address
3181 KRESTERBROOKE LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r ' <br /> Project Summary Job: 2889B1 sf ADS Carrier <br /> Date: 511/2018 <br /> lower floor By: Dave : <br /> BAYONET PLUMBING COOLING HEATING <br /> Project I • • <br /> For: Lennar Homes <br /> Notes: FBC 2017 <br /> Design In • • <br /> Weather: Tampa International AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 OF Outside db 92 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 39 OF Design TD 17 OF <br /> Daily range L. <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 21073 Btuh Structure 16218 Btuh <br /> Ducts 2020 Btuh Ducts 2360 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> none <br /> (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 23093 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 18578 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 1902 Btuh <br /> Ducts 403 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Coolin (none) <br /> Area(ft2) 179E 1793 Equipment latent load 2305 Btuh <br /> Volume(ft') 15976 15976 <br /> Air changes/hour 0.25 0.13 Equipment Total Load (Sen+Lat) 20882 Btuh <br /> Equiv.AVF(cfm) 67 36 Req. total capacity at 0.85 SHR 1.8 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade Trade <br /> Model 25HBC524AO0300 Cond 25HBC524AO0300 <br /> AHRI ref 9.154943 Coil FB4CNP025L <br /> AHRI ref 9154943 <br /> Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER <br /> Heating input Sensible cooling 20400: Btuh <br /> Heating output 24000 Btuh @ 47'F Latent cooling 3600. Btuh <br /> Temperature rise 27 OF Total cooling 24000 Btuh <br /> Actual air flow 800 cfm Actual air flow 800 cfm <br /> Air flow factor 0.035 cfm/Btuh Air flow factor 0.043 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.89 <br /> Capacity balance point= 32 OF <br /> Backup: <br /> Input= 6 kW, Output=22126 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> wri0U1tsoft- 2018-May-01 13:37:13 <br /> Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> 14C*Ck ...ent\288981 sf ADS template 1.5-2ton Carrierrup Calc=MJ8 Front Door faces: E <br />
The URL can be used to link to this page
Your browser does not support the video tag.