My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19984
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19984
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2019 11:12:44 AM
Creation date
5/23/2019 11:12:43 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19984
Building Department - Name
LENNAR HOMES LLC
Address
3181 KRESTERBROOKE LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> Manual S Compliance Report Job: 2889B1sf ADS Carrier <br /> Date: 5/1/2018 <br /> upper floor By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> Project I • • <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 92.4°F Sensible gain: 12796 Btuh Entering coil DB: 75.8°F <br /> Outdoor design WB: 77.4°F Latent gain: 2056 Btuh Entering coil WB: 62.9°F <br /> Indoor design DB: 75.0°F Total gain: 14852 Btuh <br /> Indoor RH: 50% Estimated airflow: 600 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L <br /> Actual airflow: 600 cfm <br /> Sensible capacity: 15300 Btuh 120% of load <br /> Latent capacity: 2700 Btuh 131% of load <br /> Total capacity: 18000 Btuh 121% of load SHR: 85% <br /> i <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 11001 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> I ' <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L <br /> Actual airflow: 600 cfm <br /> Output capacity: 13453 Btuh 122% of load Capacity balance: 20 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> ' I <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 600 cfm <br /> Output capacity: 3.1 kW 97% of load Temp. rise: 50 °F <br /> Meets all requirements of ACCA Manual S. <br /> 1 wrig17tso t® 2018-May-01 13:37:13 <br /> Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 <br /> ...ent\2889B1 sf ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces: E <br />
The URL can be used to link to this page
Your browser does not support the video tag.