Laserfiche WebLink
i <br /> IluiIdin„and n tnstru 011u l'tli(MCS) <br /> PASC .- <br /> COUNTY FI_oi,%16V Blower Door Test Report Form <br /> unn r: <br /> � Ptncertv Address: <br /> PUMA r: J Test rg eon Dar Y Name SKYETEC <br /> Test Date: I .20 Tesu,rise,11 ASSEN K H E L I F I <br /> Testereertr: MY3YG6 eurtanpt.-.904-903-1076 <br /> liklielifi@skyetec.com <br /> 402A.1.2 Testing.Building envelope air tightness shall be demonstrated by Section 402.4.1.2 <br /> The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes <br /> per hour. Testing shall be conducted with a blower doer at a prrsstrrc of 02 inch, w-g.(50 Pascals).As required by <br /> the Building Official,testing stall be conducted by an approved third party.A written repo"of the results of the test <br /> shall be signed by the party conducting the test(including Agency Namc)and pro%ided to the Building Official prior to <br /> Certificate of Occupancy issuance.Testing shall be perfotmcd at any time after creation ofall scheduled penetrations of <br /> the building thermal envelope. <br /> During testing:(check to verify condition met) <br /> Exterior windows and doors,fireplace and stove dears shall be closed,but not sealed,beyond the intended weather- <br /> stripping or other <br /> I` Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be dosed,but not sealed beyond <br /> intended infiltration <br /> 1�J Interior doors,if installed at the time of the test,shall he open <br /> VV, ,P lExterior doors for continuous ventilation systems and heat recovery ventilators shall be dosed and sealed 1 <br /> i �'1 <br /> sting and cooling systems,if installed at the time of the test,shall beturned off <br /> Supply and return registers,if installed at the time of the test,shall be fully open <br /> Vb Building volume(ft') = 24554. <br /> Q5o Airflow at 50 Pascal(CFM) _ +C <br /> ACHso Air changes per hour at 50 Pascal <br /> Q5ox 60=Vb= ACI1so(3.0ACHmhd...) <br /> Pass 'ail 0 <br /> El Outside Air mechanically introduced to space(less than 3.0 ACH) <br /> 1 hereby certify that the above envelope leakage performance results demonstrate compliance <br /> with Florida Energy Code requirements in accordance ttzth Section MZ4.1.2. <br /> Signature of TesTes ee Dale <br /> I <br />