My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19985
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19985
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2019 11:13:27 AM
Creation date
5/23/2019 11:13:25 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19985
Building Department - Name
LENNAR HOMES LLC
Address
3184 KRESTERBROOKE LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, 5 ' <br /> FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2889A1 sf ADS Carrier Builder Name: Lennar Homes <br /> Street: 3184 Kresterbrooke Lane Permit office: City of Zephyrhills <br /> City,State,Zip: FL, Permit Number: <br /> Owner. Lennar Homes Jurisdiction:611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2754.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1308.70 ft2 <br /> b.Frame-Wood,Exterior R=11.0 1114.00 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 331.50 ft2 <br /> 4. Number of Bedrooms 5 d.N/A - R= ft2 <br /> 10.Ceiling Types (2307.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2167.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 2896 b.Knee Wall(Vented) R=30.0 140.00 ft2 <br /> Conditioned floor area below grade(ft2) 0 c. R= ft2 <br /> 11.Duct <br /> s R ft2 <br /> 7. Windows(193.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH: 1st Floor 6 358.6 <br /> a. U-Factor: Dbl,U=0.54 96.00 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 221 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl, U=0.56 64.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 24.0 SEER:15.50 <br /> b.Central Unit 18.0 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 33.33 ft2 <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 <br /> SHGC: b.Electric Heat Pump 17�7 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 1.172 ft. <br /> Area Weighted Average SHGC: 0.302 14.Hot water systems <br /> 8. Floor Types (2902.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1793.00 ft2 b. Conservation features <br /> b.Floor Over Other Space R=0.0 672.00 ft2 None <br /> c.other(see details) R= 437.00 ft2 15.Credits Pstat <br /> Total Proposed Modified Loads: 85.94 PASS <br /> C <br /> Glass/Floor Area: 0.067 ASS <br /> Total Baseline Loads: 85.84 <br /> I hereby certify that the plans and specifications covered by Review of the plans and <br /> this;calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance ' <br /> Dave <br /> �G� with the Florida Energy Code. <br /> D �+ rem..%r. -., •;;�• x,'f) <br /> PREPARED BY: A Before construction is completed <br /> DATE: this buildingwill be inspected for P t7 _r 0; <br /> compliance with Section 553.908 <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Code. G'Ojj <br /> MAY 0 3 2018 <br /> OWNER/AGENT: BUILDING OFF CIA[ ' i <br /> DATE: DATE: 511 <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. <br /> 5/1/2018 1:11 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page.1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.