Laserfiche WebLink
i <br /> BuildingAnal Job: 2575A1 sf ADS Carrier <br /> Y$I$ Date: 5/1/2018 <br /> lower floor By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> Project I • • <br /> For: Lennar Homes <br /> Design Conditions <br /> Location: Indoor: Heating Cooling <br /> Tampa Intl AP, FL, US Indoor temperature(°F) 70 75 <br /> Elevation: 10 ft Design TD (°F) 38 16 <br /> Latitude: 28°N Relative humidity (%) 50 50 <br /> Outdoor: Heating Cooling Moisture difference(gr/lb) 33.5 53.9 <br /> Dry bulb ff) 32 91 Infiltration: <br /> Daily range(°F) - 14 ( L ) Method Simplified <br /> Wet bulb (°F) - 77 Construction quality Semi-tight <br /> Wind speed (mph) 15.0 7.5 Fireplaces 0 <br /> • <br /> Component Btuh/ftz Btuh % of load <br /> Walls 5.3 5016 31.8 ucis <br /> Glazing 29.2 2565 16.3 nfiltration <br /> Doors 22.7 450 2.9 wall <br /> Ceilings 1.7 55 0.4 <br /> Floors 4.0 4329 27.5 <br /> Infiltration 1.9 1966 12.5 <br /> Ducts 1368 8.7 <br /> Piping 0 0 Floors <br /> Humidification 0 0 Glazing <br /> Ventilation 0 0 Doors Other <br /> Adjustments 0 <br /> Total 15750 100.0 <br /> Component Btuh/ftz Btuh % of load <br /> Walls i 2.8 2669 23.5 ! Internal Gains <br /> Glazing 56.3 4953 43.6 wall <br /> Doors 18.6 368 3.2 <br /> Ceilings 2.0 65 0.6 Ducts <br /> Floors , 0 0 0 <br /> Infiltration 0.4 456 4.0 <br /> Ducts 1657 14.6 nfiltration <br /> Ventilation 0 0 other <br /> Internal gains 1200 10.6 Doors <br /> Blower 0 0 <br /> Adjustments 0 <br /> Total 11368 100.0 Glazing <br /> Latent Cooling Load= 1216 Btuh <br /> Overall U-value= 0.150 Btuh/ftz-°F <br /> Data entries checked. <br /> ` -Fp- wrightsoft- 2018-May-01 09:13:07 <br /> Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> ACCK ..ment%2575A sf ADS template 1.5-2ton Carrier.rup Cale=MJ8 Front Door faces: E <br />