My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19988
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19988
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2019 11:15:03 AM
Creation date
5/23/2019 11:15:01 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19988
Building Department - Name
LENNAR HOMES LLC
Address
3193 KRESTERBROOKE LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Job: 2575A1 sf ADS Carrier <br /> Project Summary Date: 5/1/2018 <br /> upper floor By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> Project • <br /> For: Lennar Homes <br /> i <br /> Notes: FBC 2017 <br /> Design Information <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 32 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 38 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 10857 Btuh Structure 15634 Btuh <br /> Ducts 1805 Btuh Ducts 2140 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0, Btuh <br /> none (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 12662 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 17774 Btuh <br /> I <br /> Method Simplified Latent Cooling Equipment Load Sizing j <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2943. Btuh <br /> Ducts 374 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating cooling (none) <br /> Area(ft2 1491 1491 Equipment latent load 3317 Btuh <br /> Volume(ft') 12077 12077 <br /> Air changes/hour 0.27 0.14 Equipment Total Load (Sen+Lat) 21091' Btuh <br /> Equiv.AVF (cfm) 54 29 Req. total capacity at 0.85 SHR 1.7 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade Trade <br /> Model 25HBC524AO0300 Cond 25HBC524AO0300 <br /> AHRI ref 9154943 Coil FB4CNP025L <br /> AHRI ref 9154943 <br /> Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER <br /> Heating input Sensible cooling 20400 Btuh <br /> Heating output 24000 Btuh @ 47°F Latent cooling 3600 Btuh <br /> Temperature rise 27 OF Total cooling 24000 Btuh <br /> Actual air flow 800 cfm Actual air flow 800 cfm <br /> Air flow factor 0.063 cfm/Btuh Air flow factor 0.045 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.84 <br /> Capacity balance point= 17 OF <br /> Backup: <br /> Input= 3 kW, Output= 11787 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> -Fk- wr1ohtsoft- 2018-May-01 09:13:07 <br /> •�^ Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 <br /> �` ...ment\2575A sf ADS template 1.5-2ton Carrier.rup Calc=MA Front Door faces: E <br />
The URL can be used to link to this page
Your browser does not support the video tag.