Laserfiche WebLink
ROCK- IT SYSTeM 4.0 <br /> SYSTem sPeclFlCaTlons <br /> Max No.of Panels 300 Modules per ground lug Materials 300 Series Stainless, <br /> 6000 Series Aluminum <br /> Max System Voltage 1000VDC Coating Black Andodization/Mill Finish <br /> Class A Fire Rating With UL1703Type 1 Rated Lug Specifications Burndy CL50-1TN Ground Lug <br /> Modules,see note below. (UL Listing#KDER E9999) <br /> Leveling Range 3-4" Ground Wire 14 AWG-4 AWG Copper <br /> Per above Lug spec. Ground Wire <br /> Rock-It Slide Comp Range 3" Max Module Size 64.96"(1650mm)x <br /> Rock-It SlideTile 7" 39.05"(992mm)x 2"(50mm) <br /> Min/Max Roof Slope 1/2:12/12:12 Max Downforce/Uplift Rating 45 PSF <br /> Max Anchor Spacing(35mm/40mm) 72" Rock-It Mount Load Rating 5471bs with Single 5/16"Lag 3.0 <br /> Max Anchor Spacing(32mm) 48" Safety Factor <br /> Skirt Box QTY 6 units Slide Fastening Hole 5/16"diameter <br /> Mount Box QTY 12 units Module Cantilever Maximum cantilever is 1/3 <br /> Rock-It Slide Box QTY 50 units bracket spacing <br /> Coupling Box QTY 12 units Warranty 20 Year Material and Workman- <br /> ship <br /> Codes:National Electric Code,ANSI/NFPA 70,NEC 250,NEC 690,IRC,IBC <br /> Standards:UL 2703:First Edition,UL 1703 <br /> *tcotasten solar <br /> ',�'I:rnlvatul$u�Ji ROCK-IT SYSTEM <br /> F caliwi:iTof mieI MM ID CODE:GGT-Q2-2016 <br /> CONfONM115T0 uL I]03 CD 1IFCRM5TOUL2703 <br /> IOAD q/.TNG:SEE I NSTILLATNIN <br /> .vawwv.n �FldN G1WG5 <br /> Nip-.' ♦O ASSOOA�hOvnnl'H SVECI:IC MOVVlES <br /> The EcoFasten Solar Rock-It System is a rooftop PV racking system consisting of 6000 Series Aluminum and 300 Series <br /> Stainless Steel components.The Rock-It System includes the rack components but does not include the PV panels, <br /> inverters or electrical components.The PV modules to be used with Rock-It shall be certified under UL 1703.The <br /> system shall be used on steep slope roofs mounted over a Class A fire rated roofing material and attached to the roof <br /> structure using 5/16"diameter,minimum 4"long 300 series Stainless Steel lag bolts with minimum thread <br /> embedment depth of 21/2"into the roof structure. <br /> Periodic re-inspection for loose components <br /> The system is subject to re-inspection as required by the PV module manufacturer or by the Authority Having <br /> Jurisdiction.Re-inspection,as required,should include evaluation of any loose components or loose fasteners.All <br /> loose components and fasteners should be secured in accordance with these instructions.The system should also be <br /> evaluated for any evidence of corrosion.Any corrosion should be removed.Any affected part should be cleaned or <br /> replaced in accordance with these instructions. <br /> A <br /> ,O,,"Ec®Fasten Solar° <br /> V <br /> www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 15 <br />