Laserfiche WebLink
Enphase IQ 6 and IQ 6+ Micr®inverters <br /> INPUT DATA(DC) IQ6-60-2-US IQ6PLUS-72-2-US <br /> Commonly used module pairings' 195 W-330 W+ 235 W-400 W-+ <br /> Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules <br /> Maximum input DC voltage 48 V. 62 V^ <br /> Peak power tracking voltage 27 V-37 V 27 V-45 V <br /> 0 erating range 16 V-48 V 16 V-62 V <br /> Min/Max start voltage 22 V/48 V 22 V/62 V <br /> ..Max DC short circuit current(module Isc) 15 A', 15 A' <br /> Overvoltage class DC port II II <br /> -.._..................- ................__...--._......-- - _.., ._.. ._......_.._.... . ..... -- -.........._....-- - --.--- <br /> DC port backfeed under single fault 0 A' 0 A <br /> PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; <br /> AC side protection requires max 20A per branch circuit <br /> OUTPUT DATA(AC) IQ 6 Microinverter IQ 6+Microinverter <br /> Peak output power 240 VA 290 VA <br /> Maximum continuous output power 230 VA 280 VA <br /> Nominal(L L)voltageleangez - 240 V/2 11-264 V- 208 V/183-229 V 240 V/211-264 V 208 V/183-229 V <br /> Maximum continuous output current 0.96 A 1.11 A 1.17 A 1.35 A <br /> Nominal frequency -._-_--------._._.:._..._. -------.---.__.. ..._._-__..-- --._._......._..__.-- -_. ..._.. . _.....---___..__...__..._.._. --__---...._. _.-.. <br /> - --- - - - -Y--- --- 60 Hz 60.Hz. <br /> Extended frequency range 47-68 Hz 47-68 Hz <br /> _.__.................__.._.................. <br /> _ ......__....- - <br /> Power factor at rated.power 1.0 1.0 <br /> Maximum units per 20 A(L-L)branch circuit 16(240 VAC) 13(240 VAC) <br /> 14(208 VAC) 11 (208 VAC) <br /> Overvoltage-class AC port III III <br /> AC port backfeed under single fault 0 A 0 A <br /> __..._._.......-.-_.-__.__....__- ...___...___.____._._..... __.._.._....__-._._____—________..._._------- <br /> Power factor(adjustable) 0:7 leading..:0.7lagging 0.7leading 0.7,lagging:. <br /> EFFICIENCY @240 V @208 V @240 V @208 V <br /> CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% <br /> MECHANICAL DATA <br /> Ambient temperature range -4000 to+65°C <br /> Relative humidity range 4%to 100%(condensing) <br /> Connector type MC4locking type <br /> Dimensions(WxHxD) 219 mm x 191 mm x 37.9 mm(without bracket) <br /> Weight 1.29 kg(2-84 Ibs) <br /> Cooling Natural convection-No fans <br /> Approved for wet locations Yes <br /> Pollution degree PD3 <br /> Enclosure Class Ildouble-insulated, <br /> Environmental category/UV exposure rating NEMA Type 6/outdoor <br /> FEATURES <br /> Communication Power line <br /> Monitoring Enlighten Manager and MyEnlighten monitoring options <br /> Compatible with Enphase IQ Envoy <br /> Disconnecting means The AC and DC connectors have been evaluated and approved by U L for use'as the load-break <br /> disconnect required by NEC 690. <br /> Compliance CA Rule 21 (UL 1741-SA) <br /> UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, <br /> CAN/CSA-C22.2 NO.107.1-01 <br /> This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and <br /> NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC <br /> and DC conductors,when installed according manufacturer's instructions. <br /> 1.No enforced DC/AC ratio.See the compatibility calculator at httos-//enohase.com/en-us/support/module-compatibility. <br /> 2.Nominal voltage range can be extended beyond nominal if required by the utility. <br /> To learn more about Enphase offerings,visit enphase.com <br /> ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. � 6 N P H AS E. <br /> 2018-01-25 <br />