My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20061
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20061
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 12:00:40 PM
Creation date
5/28/2019 12:00:39 PM
Metadata
Fields
Template:
Building Department
Company Name
HIBACHI RESTAURANT
Building Department - Doc Type
Permit
Permit #
18-20061
Building Department - Name
BEAR STEARNS COMMERCIAL MORTGAGE
Address
7306 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Chapter 3—System Design <br /> Page 3-14 <br /> FtEV.5 <br /> Pryer— Multiple Nozzle Protection PIPING LIMITATIONS <br /> Fryers exceeding the coverage of a single nozzle can be Once the nozzle placement and quantity of tanks has been <br /> divided into modules.Each module must not exceed the maxi- determined, it is necessary to determine the piping configura- <br /> mum area allowed for a single nozzle.However,when utilizing tions between the tank and the nozzles.This section contains <br /> multiple nozzle protection,the longest side allowed for a fryer the guidelines and limitations for designing the distribution <br /> with drip board can be used, regardless of whether the fryer piping so that the wet chemical agent will discharge from the <br /> has a drip board or not. nozzles at a proper flow rate.These limitations must also be <br /> referred to when selecting the mounting location for the tanks. <br /> The maximum size fryer that can be modularized is 864 sq in. <br /> (5574 sq cm). The maximum pipe lengths are based on internal pipe volume. <br /> Each size tank is allowed a minimum and maximum total <br /> Design-requirements for multiple nozzle fryers are broken volume of piping,calculated in milliliters. <br /> down as follows: <br /> There is no need to distinguish between what portion of the <br /> 1. If the fryer includes any dripboard areas, measure both the piping is supply line and what portion is branch line.Only the <br /> internal length (front to back)and width of the frypot total volume of the complete piping network has to be consid- <br /> portion.Then measure the internal length and width of the ered. <br /> overall hazard area,including any dripboard areas. <br /> Determine the area of both the frypot and the area of the Volume Chart <br /> overall vat by multiplying corresponding length and width 1/4 in.pipe=20.5 mis/ft <br /> dimensions. <br /> 3/8 in.pipe=37.5 mis/ft <br /> 2. Divide the frypot or overall vat into modules, each of which 1/2 in.pipe=59.8 mis/ft <br /> can be protected by a single nozzle,based on the maxi- <br /> mum dimension and area coverage of the nozzle as speci- 3/4 in.pipe=105.0 mis/ft <br /> fied in"Design Chart." <br /> • If the module considered does not include any portion of Tank Chart <br /> the dripboard, use only the maximum frypot area and - n;• <br /> maximum dimension listed in the"Design Chart." . *Maximum ,�;. `' •` <br /> Volume Allowed` <br /> • If the module considered includes any dripboard areas, Maximum Between First <br /> use both the maximum frypot area and dimension listed Maximum Pipe Nozzle and <br /> in the"Design Chart", and the maximum overall area Tank Flow Volume Last Nozzle <br /> and dimension listed in the"Design Chart" Size Numbers (milliliters) (milliliters) <br /> 1.6 Gallon 5 1500 600 <br /> 3. None of the maximum dimensions may be exceeded.If PCL-160 <br /> either the maximum frypot or the overall sizes are 3.0 Gallon 10 1910 1125 <br /> exceeded,the area divided into modules will need to be PCL-300 <br /> redefined with the possibility of an additional nozzle. 4.6 Gallon 14 3400 3000 <br /> PCL-460 <br /> ►Design Chart 4.6 Gallon 15 2600 2000 <br /> PCL-460 <br /> Longest Vat Coverage 6.0 Gallon 19 4215 1688 <br /> Side Coverage with Drip PCL-600 per side <br /> Option 1 27 3/4 in. 324 in2 500 in2 6.0 Gallon 20 3465 1313 <br /> " (70.5 cm) (2090 cm2) (3226 cm2) I PCL-600 per side <br /> Option 2 25 3/8 in. 371 in2 495 in2 ►*All piping, including nozzle drops, must be included in the <br /> (64.5 cm) (2394 cm2) (3194 cm2) piping calculations. <br /> Minimum Pipe Volumes for a Fryer, Range,and Wok <br /> Cylinder Size Entire System At or before appliance <br /> PCL 160 239 ml-1 Flow Pt 180 ml-1 Flow Pt <br /> PCL 300 300 ml-4 Flow Pts 239 ml-2 Flow Pts <br /> PCL 460 660 ml- 10 Flow Pts 180 ml-2 Flow Pts <br /> PCL 600 960 ml-14 Flow Pts 120 ml-2 Flow Pts <br /> ULEX 3830 <br /> December 1,2009 <br />
The URL can be used to link to this page
Your browser does not support the video tag.