Laserfiche WebLink
TYPICAL HEAD ANCHORAGE �(Yli'!a]/LVV!/ •I/n"'" <br /> MIN.EMBEDMENT WINDOW SYSTEMS L� <br /> MIN.EDGE DIST. SEE TABLE 1 SUBSTRATE <br /> BY OTHERS 1900 SW 44TH AVE. <br /> SEE TABLE 1 114"MAX.SHIM SEE TABLE 1 <br /> QCALA,FLORIDA 34474 <br /> SUBSTRATE BY OTHERS Wm.CWS.CC <br /> SEE TABLE 1 <br /> MIN.EMBEDMENT <br /> PERIMETER SEALANT SEE TABLE 1 MIN.EDGE DIST, 8100 PVC <br /> BYNSTALLER SEE TABLE 1 <br /> INSIDE AND OUT SINGLE HUNG <br /> INSTALLATION ANCHOR SEALANTBEHIND l� SEE TABLET IMPACT <br /> FLANGE BY INSTALLER 114"MAX.SHIM <br /> O Q Z 3 QZ� <br /> O W 0 Q W❑W <br /> Z WJ❑ <br /> ❑ Z W Z O m <br /> PERIMETER SEALANT Z z W <F- 2 <br /> BY INSTALLER O O�O Q=OF o <br /> INSTALLATION ANCHOR INSIDE AND OUT U U N�Z(L <br /> SEE TABLE 1 SEALANT BEHIND Z ZO U❑--Z U <br /> FLANGE BY INSTALLER Q F Z u'�OZ O Li Z <br /> >- ¢ x0_ <br /> CONTINUOUS DOUBLE 3116'BEADS OF B HORIZONTAL SECTION O U F=Z uj <br /> TREMGLAZE U1600 SEALANT AROUND 6 TYPICAL JAMB ANCHORAGE W O❑�y O W W <br /> PERIMETER AT ALL INDICATED POINTS p Z W O�L 1- <br /> BETWEEN FRAME AND BUCK BY INSTALLER. T~ W W to <br /> 1/4"MAX.SHIM a I- a a <br /> SLANT BEHIND "IttIllpf" <br /> FLANGE BY INSTALLER ,T y. <br /> PERIMETER SEALANT <br /> PERIMETERS MIN.EMBEDMENT �v No 58201 <br /> BY SEE TABLE 1 <br /> INSIDE AND OUT <br /> SUBSTRATE BY OTHERS �9= STATE OF .•u <br /> �+ <br /> SEE TABLE 1 .,p„••Z O R 1 D P;��2`C <br /> SEE TABLE DIST. 'SS/ONAL����� <br /> VERTICAL SECTION ��/✓riII11�11"` <br /> Q <br /> TYPICAL SILL ANCHORAGE <br /> O 9122/2017 <br /> TABLE I:APPROVED INSTALLATION FASTENERS LUCAS A.TURNER,P.E. <br /> SUBSTRATE TYPE ANCHOR FL PE#58201 <br /> PERIMETER MIN.EMBEDMENT MIN.EDGE DIST. PERIMETER SEALANT 1239 JABARA AVE. <br /> CONCRETE(2.0 KSI MIN.) 3116'ITN TAPCON 1-112" 1.1/8' BY INSTALLER NORTH PORT,FL 34288 <br /> O INSIDE AND OUT T-FILLED CMU(117 PCF MIN.) 3/1fi'ITN TAPCON 1" PH.941-360-1574 <br /> C HORIZONTAL SECTION <br /> CO 6 BOX FRAME INSTALLATION SHEET DESCRIPTION: <br /> GROUT-FILLED CMU(ASTM C-90) 3116'ELCO ULTRACON 1.1/4' 2-1/2' HEAD AND SILL SIMILAR FOR BOX INSTALLATION <br /> 3/16"RW TAPCON INSTALLATION DETAILS <br /> 2X MIN.SOUTHERN PINE(G=0.55) 1-3/8' 718' <br /> OR ELCO ULTRACON FLANGE REMOVAL NOTE:PARTIALLY OR FULLY REMOVING THE FLANGE, <br /> 2XMIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-3/8' 718' UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: DRAWN BY.- GATE: <br /> BAT 06/18l12 <br /> 16 GAUGE(0.060")MIN.STEEL STUD 010-16 HILTI KWIK•FLExoR ITW FULL THREAD 7116" -MIN.1/4"FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED D Ga: R V.: <br /> (33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060' INSIDE AND OUT,FULL PERIMETER,BY INSTALLER. <br /> 1/8-ALUM.(6063-T5 MIN.)OR 010 GRADE 5 SELF-TAPPING/ FULL THREAD -PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS CWS-812 C <br /> 118'STEEL(33 KSI MIN.) DRILLING SCREW hIRU 0.125" 7116' SHOWN FOR FLANGE WINDOWS. scALE: SHEET <br /> 1:2 6 OF 6 <br />