My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20105
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20105
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2019 7:40:11 AM
Creation date
5/28/2019 2:17:34 PM
Metadata
Fields
Template:
Building Department
Company Name
CROWN CASTLE GT COMPANY LLC
Building Department - Doc Type
Permit
Permit #
18-20105
Building Department - Name
CROWN CASTLE GT COMPANY LLC
Address
38522 A AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
140
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
tnxTOWer Job Zephyrhills (BU 816298) Page of 52 <br /> Project Date <br /> Professionals Tower ionals ineerirrg TEP No. 26146.157540 16:21:19 06/04/18 <br /> 326 Tiyon Road <br /> Raleigh,NC27603 Client Designed by <br /> Phone:(919)661-6351 Crown Castle on aobre <br /> FAX:(919)661-6350 9 <br /> Tower Input Data <br /> The main tower is a 4x free standing tower with an overall height of 287.67 ft above the ground line. <br /> The base of the tower is set at an elevation of 0.00 ft above the ground line. <br /> The face width of the tower is 10.00 ft at the top and 45.54 ft at the base. <br /> This tower is designed using the TIA-222-G standard. <br /> The following design criteria apply: <br /> Tower is located in Pasco County, Florida. <br /> Basic wind speed of 106 mph. <br /> Structure Class 11. <br /> Exposure Category C. <br /> Topographic Category 1. <br /> Crest Height 0.00 ft. <br /> Deflections calculated using a wind speed of 60 mph. <br /> Pressures are calculated at each section. <br /> Stress ratio used in tower member design is 1. <br /> Local bending stresses due to climbing loads,feed line supports,and appurtenance mounts are not considered. <br /> Options <br /> Consider Moments-Les Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules <br /> Consider Moments-Horizontals Assume Legs Pinned Calculate Redundant Bracing Forces <br /> Consider Moments-Diagonals -NI Assume Rigid Index Plate Ignore Redundant Members in FEA <br /> Use Moment Magnification Use Clear Spans For Wind Area SR Leg Bolts Resist Compression <br /> Use Code Stress Ratios Use Clear Spans For KL/r All Leg Panels Have Same Allowable <br /> 4 Use Code Safety Factors-Guys Retension Guys To Initial Tension Offset Girt At Foundation <br /> Escalate Ice Bypass Mast Stability Checks \I Consider Feed Line Torque <br /> Always Use Max Kz Use Azimuth Dish Coefficients Include Angle Block Shear Check <br /> Use Special Wind Profile \I Project Wind Area of Appurt. Use TIA-222-G Bracing Resist.Exemption <br /> Include Bolts In Member Capacity Autocalc Torque Arm Areas Use TI_A-222-G Tension_Splice Exemption <br /> Lee Bolts Are At Top Of Section Add IBC.6D+W Combination Poles <br /> 4 Secondary Horizontal Braces Leg -\I Sort Capacity Reports By Component Include Shear-Torsion Interaction <br /> Use Diamond Inner Bracing(4 Sided) Triangulate Diamond Inner Bracing Always Use Sub-Critical Flow <br /> SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Use Top Mounted Sockets <br /> SR Members Are Concentric <br />
The URL can be used to link to this page
Your browser does not support the video tag.