Laserfiche WebLink
Single _Family Dwelling:: <br /> Plan-Review Comments . . <br /> 1. F.F:E. shall be:a:minimum-of 8"_above.the road elevation and an engineered.site.plan. . <br /> I. Lotsshall be graded.to.comply with R401.3 of the F.B.C. <br /> 3. ;Compaction.test required if 24" or more:of ,fill dirt is brought in'at any one place. <br /> 4:. :Tie in survey required before'pounng concrete.' <br /> 5. Driveways require a R.O.W, use permit: All 4:sides of driveway thru the-sidewalk shall have. <br /> expansion material:. :. . <br /> 6. All setbacks.shall be met... <br /> 7.: ;All property markers shall be-uncovered and marked at time of first.inspection: <br /> 8:- :All A.D.A. requirements.shall be met.: . <br /> 9. No:electric,plumbing,-mechanical; or framing shall be covered without an inspection and <br /> approval first. . <br /> 10. A11 Garages shall;comply:.with:section R302.6 of the:F.B:C:;(Fire Separation). <br /> 11:Appliances.shall'not:be installed in:a location'where subject to mechanical damage unless. <br /> 1?rotected.bY1?p <br /> a roved barriers. M303..4 o£the F.B.0 <br /> .. . . .- <br /> 12. Water heaters shall comply with section:P607.3 of the.F:B.C: <br /> 13. Foundation supports for-A/C-units.shall be raised at least 3" above finished grade. M1308.1. <br /> 14. Return air in All bedrooms.F.B.C. 1MI1620.4._ . <br /> 15: Smoke detectors are to b-e installed:in accordance with:R313:1 of the:F.B.C. <br /> 16: All glazing requirements are to be in accordance with R308.4_'of the F.B.C.-. <br /> 17.All means,of egress are o.be in:accordance with R311.of the F.B.C. <br /> 18.;`.`Green gypsum board shall-not be used as a backer.in showers or tubs. R702.442 F.B.C. <br /> 19. Combination-type A.FCI breakers are.required,at all.locations requiring.an AFCLtype breaker: <br /> 20. Carbon monoxide.alarms"Will be required in new construction that uses fossil-burning heating <br /> :or appliances or an attached garage. ;They shall be,installed in accordance with.the F.B.0 <br /> 21. All plumbing, mechanical and.electrical shall:be separate from unit to.unit- This includes all <br /> undergroundplumbingand electric: <br /> 22. All 2016.N.E C. Codes will be enforced.. • . <br /> 23: Tamper- Resistant Receptacles in accordance with 406:11- of the 2016 N.E:C <br /> 24.Ah accordance:.with the Land:Development Code,lots shall be-sodded before final at least10 <br /> feet around:the structure. .. : _ <br /> 25. Blower door:test and blown in insulation card shall be provided before C:.O. <br /> 26 A copy ofthe energy cacls.shall be with permit.at all times. <br /> 27 Cony of final insulation report shall be:provided with:yerniit�before TnaL <br /> F.F:E.-Finished Floor Elevation <br /> F:B.C=Florida Building:Code 6 h Edition <br /> R.O.W.-Right of Way <br /> A-D.A.-Americans with Disabilities'Act , : N.E.C.-National Electric Code(2011) <br />