ing e ami y we ing <br /> Plan Review Comments: <br /> 1: RRE. shall be a minimum of.8" above.the road elevation:and an engineered site plan. <br /> 2. -Lots shall be graded to,comply with R4013 of the F.B.C. . <br /> 3. -Compaction:test required.:if 24" or more of-fill dirt is.brought in:at any one place: <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways:require a R.O:W,use permit. All 4:sides'of driveway thru the sidewalk shall have. <br /> expansion material: <br /> 6. All setbacks shall be inet:. . <br /> 7. 'All property markers shall be uncovered and'marked at time of first 'inspection: <br /> 8:. :All A.D.A. requirements.shall be met. . <br /> ...9. No:electric.plumbing,.mechanical, .or framing shall be covered without an:inspection and <br /> approval first. . .. <br /> 10. All Garages shall comply:.with:section R302:6.of the F.B.C.,(Fire Separation).: <br /> 11::Appliances shall'not:be installed in.a location where subjectto.mechanical damage unless <br /> protected'by approved:barriers-. M303.4 of the F.B:C- <br /> 12. Water heaters shall comply with section.P607.3 of the F.B.C: <br /> 13. Foundation supports:for A/C.units shall be raised at least 3'.' above finished grade, M 1308.1. <br /> 14. Return air in all,bedrooms.F.B.C. M.1620.41 <br /> 15: Smoke detectors are to be installed.in' accordance:with:R3111 of-theT.B.C. <br /> 16: All glazing requirements are to be in accordance with R308.4 of the.F.B.C. <br /> 17. All means.of egress are to:be in:accordante with R311::of the F.B.C. <br /> 18. `.`Green gypsum board"shall not be used:as a backer.in:showers or tubs. R702.4.2_F.B.C. <br /> 19..Combination-type AFCI breakers are required at all.locations requiring an AFCLtype breaker: - <br /> 20. Carbon monoxide alarms will be required in.new:construction that uses fossil-burninggli'ting <br /> :or appliances or an attached garage. They shall be.installed in accordance with.the F.B.C. <br /> = 21. All plumbing,mechanical, and:electrical shall:be.separate from unit.to unit: This includes all . <br /> underground:plumbing and electric: <br /> 22. All 2016:N.E.C. Codes will be enforced:. <br /> .23. Tamper- Resistant Receptacles in accordance with 4Q6.1 I.of the 2016 N.E:C . <br /> : .24. In accordance.with the Land.Development.Code, lots.shall be sodded before final at least 10 <br /> feet around the structure. - <br /> 25. Blower door:test and blown in insulation card shall be provided before C.O. <br /> 26 A come of the energy eacls.shall be with permit-at all dihi s. <br /> 27. Copy of final insutatioir report shall be:tirovided with:permit before:final <br /> F.F.E.-Finished Floor Elevation .:. <br /> F.B.0 Florida Building Code 6a'Edition. <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans-with Disabilities Act N.E:C.-National-Electric Code-(2011) <br />