Laserfiche WebLink
is g. e Faml y Dwe in <br /> g _ <br /> n Plan Review Comore is <br /> I. F.F.E. shall be a minimum_of 8 above the road.elevation and an engineered site,plan. <br /> 2. Lots..shall be graded.to.comply with R401.3 of the'F.B:.C: <br /> .3. ;Compaction test required if 24 or more.of fill dirt is.brought_in:at any one place. <br /> 4: Tie in' survey required before pouring concrete. <br /> 5. Drive ways:require a R.O:W. use permit.: All 4:sides of driveway thru the sidewalk shall have <br /> expansion material:. <br /> 6. All setbacks.shall,be met.:. . <br /> 7._ All property:markers shall be_uncovered and marked at time of first inspection: <br /> . <br /> I. <br /> .8:. :All A.D.A:requirements shall be met. . <br /> 9.: .No electric;plumbirig,_mechanicaL.or framing shall be covered without an.inspection and <br /> approval first.. . <br /> 10. All;Garages shall:complymith-section R302:6-of the:F.B.C::(Fire S:eparation). <br /> -11.Appliances:shall not be installed in.a location where subjectto.mechanical damage:unless. <br /> pfotected-by approved barriers. M303'.4 of the F.B.0 <br /> 12. Water heaters shallcomply:with section P607.3 of the F.B.C: <br /> 13. Foundation supports for.A/C units shall'b'eraised at least 3"above finished grade, M1308.1. <br /> 14. Return air in all:bedrooms. F.B.C. M1620,4, <br /> 15. Smoke detectors are to be installed in accordanee.with R313:1 of the F.B.C. <br /> 16::A11 glazing requirements-are:.to b.e in accordance with R308.4.of the F.B.C. . <br /> 17. All means.of egress are to be in accordance with-R311`of the F.B.G. <br /> 18. "Green gypsum.board" shall-not be used as.a backer in:showers or-tubs. R702:4:2-F.B.C: <br /> 19.-Combination-typeAFCI breakers.are,required at all.locations requiring an AFCI,type breaker: <br /> 20: Carbon monoxide.alarms.will be required in.new:construction that uses fossil-burning heating <br /> or appliances or an attached garage: They shall be,installed in accordance with the F.B.C. <br /> .21. All plumbing,mechanical,-and electrical shall be separate from unit to.unit: This includes all. <br /> un ergroun p urnbin acid electric: <br /> 22. All 2016:N.E:C: Codes Will be enforced. <br /> 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N:E:C <br /> 24. In accordance.With the Land:.Development.Code, lots shall be.sodded before final of least 10 <br /> feet "around the structure. <br /> 25. Blower door test and blown in insulation card shall be provided before C.-O. <br /> 26.A copy ofthe energy cacls.shall be with permit-at-all times <br /> .27.. Copy of final insulation report shall be:provided with:perihut before:fnaL <br /> F.F.E.-Finished Floor.Elevation <br /> F.B.C-Florida Building Code 6 h Edition <br /> R.O.W.-Right of Way <br /> A.D.A:-Americans with Disabilities Act N.E.C.-.National Electric Code(2011) <br />