My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20121
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20121
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2019 7:40:43 AM
Creation date
5/28/2019 2:23:20 PM
Metadata
Fields
Template:
Building Department
Company Name
SAN ANTONIO CF CREDIT UNION
Building Department - Doc Type
Permit
Permit #
18-20121
Building Department - Name
SAN ANTONIO CF CREDIT UNION
Address
7301 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A <br /> EnCon Services, Inc. <br /> Sign Design Calculations <br /> Job Description PREPARED BY: EnCon Services, Inc. <br /> San Antonio Citizens Federal Credit Union PO Box 3613 <br /> 7301 Gall Blvd Apollo Beach, FL 33572 <br /> Zephyrhills, FL 33541 P 813-655-3373 <br /> 36"x 132"Wall Sign F 813-655-9814 <br /> Design per Florida Building Code,6th Edition(2017),Section 16 Wind Load, FLEB#9394 <br /> ASCE 7-10, Load Case: D+0.6W <br /> Design Specifications Nathan P. Presnell, PE <br /> Risk Category II FLPE 77696 <br /> Kzt 1 <br /> Exposure Factor C <br /> Kd 0.85 <br /> Kz 0.98 `o�rpllilrll!►/�jl,, <br /> V 150 (mph) <br /> GCp-GCpi 1.1 Zone 4, H<60 Feet ���Q'•.•C E 1V .S <br /> Wind Pressure 52.8 (psf) <br /> AF <br /> NO 7769 <br /> Sign Information <br /> Height 3.00 ft <br /> � STA OF <br /> Width 11.00 ft <br /> Thickness 0.67 ft �O"O�,ri••;cC• I R IV <br /> Distance rade to top 30 ft �'�OS�QIVAL, ������� <br /> Wind Shear Force 63.65 (lb) <br /> Weight of Sign 330 (lb) DATE SIGNED: <br /> Total Shear Force= 336.08 (lb) 7/11/2018 <br /> Total Tension Force= 1045.02 (lb) <br /> Required Provided <br /> Fastener size Nominal 3/8 3/8 <br /> Minimum number of fasteners 6 6 <br /> Shear Force per fastener(lb) 56.0 280 <br /> Tension Force per fastener(lb) 174.2 352 <br /> Combination Tension and 0.69 <1 O.K. <br /> Shear ratio <br /> THREADED ROD THROUGH WALL IS PREFERRED IN ALL INSTANCES. IF IT IS NOT POSSIBLE TO USE THREADED ROD,SEE CHART BELOW <br /> FOR APPROPRIATE ANCHOR SELECTION.SIZE AND NUMBER REQUIRED ARE NOTED IN THE CHART ABOVE. <br /> WALL STRUCTURE ANCHOR TYPE <br /> WOOD BLOCKING LAG BOLT(3"EMBEDMENT)THROUGH BLOCKING <br /> EIFS OVER 5/8'PLYWOOD LIBERTY TOGGLE BOLT OR THRU BOLT WITH SLEEVE <br /> HOLLOW CONCRETE BLOCK,BRICK SLEEVE ANCHOR(1-1IT EMBEDMENT) <br /> SOLID CONCRETE WEDGE ANCHOR(2-1/2°EMBEDMENT) <br /> CMU,SOLID CONCRETE,BRICK HILT[HIT ROD W/HY-70 ADHESIVE(31/2"EMBEDMENT) <br /> ALL ANCHORS SHALL BE CHOSEN AND PLACED IN ACCORDANCE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS <br /> 7/11/2018 <br /> San Antonio Citizens Federal Credit Union Zephyrhills 36in x 132in Wall Sign <br />
The URL can be used to link to this page
Your browser does not support the video tag.