MODEL DESIGNATION: Simonton Double Hung Series 43-17 Vinyl Window ���`p1pLyvyv��4
<br /> MAXIMUM OVtRALL NOMINAL SIZE: See Size Chart : ..O.E........ � ZZ
<br /> % l I/7/2017
<br /> DESIGN PRESSURE RATING: • See Size Chart �-Jr: No 58201 'A: LUCAS A.TURNER,P.E.
<br /> FL PE®58201
<br /> TURNER ENGINEERING @
<br /> USABLE CONFIGURATIONS: X 9'•. BTATE OF W� CONSULTING,INC.
<br /> X �O•t`'•,'s T,.•"2�� (CO 129AJ BARA 7AV)E.
<br /> 3
<br /> ,�� t C R:�'�OHO•`,, NORTH PORT,FL 34288
<br /> N RA D C.RIPTION• The head, sill, and side jambs are extruded PVC. The wall thickness zsS20NA„ p�`` PH.941-380-1574
<br /> through which the anchor screw penetrates is a minimum of 0.142".
<br /> TABLE 1: INSTALLATION FASTENERS TABLE
<br /> ED SUBSTRATE TYPE ANCHOR TYPE MIN.EMBED MIN EDa
<br /> 1
<br /> A CONCRETE 2 KSI MIN. } 16-ITW TAPCON 1-1/2- 1 1 8-
<br /> B ASTM C90 117 PCF MIN. U 3/15'IIW TAPCON 1' 2'
<br /> C 2X MIN.SOUTHERN PINE WOOD 3/I6-rrW TAPCON 1-3/8' 3/4'
<br /> D X MIN SOUTHERN PINE WOOD #10 WOOD SCREW 1-3/8. 3/4'
<br /> Gm0.55
<br /> E 16 GAUGE 0.060 MIN.STEEL 10-16 ITAI T06 FULL THREAD 1/2- ,
<br /> STUD 3K51 YI D MIN SELF-DRIWNG SCREW
<br /> 1 8 PLUM.8063-T5 MIN. 10 RADE SELF- IN /
<br /> F 1 e'STE 36 KSI MIN. DRILLING SCREV/ FULL THRE 1 2'
<br /> NOTES:
<br /> 1.This Installation has been evaluated for use In locations adhering to the Florida Building Code outside the HVHZ,and where pressure requirements as determined by ASCE 7 Minimum Design Leeds for Buildings and
<br /> Other Structures do not exceed the design pressure ratings herein.
<br /> 2.Far anchorage requirements In various substrates see Table 1.A minimum distance of 3'shall be maintained between any two installation fasteners.
<br /> 3.All Interior and exterior perimeter surfaces or the window must be caulked.
<br /> 4.Anchor type,size,spacing,embedment,and edge distance shall be as specified in these drawings.
<br /> 5.Anchor embedment to substrate shag be beyond wall dressing or slurm.For masonry,openings with wood bucks less than 1-1120 thick,embedment shall be beyond wood bucks,if used,and Into masonry substrate.
<br /> Woad buts with masonry are optional.
<br /> 6.Wood or masonry openings,bucks,and buck fasteners,by others,shag be properly designed and installed to transfer wind bads to the structure.
<br /> 7.The responsibility for selection of Simonton products to meet any applicable local laws,building codes,ordinances,or other safety requirements rests solely with the archdect,building owner,or contractor.
<br /> 8.Shims am required where gaps of greater than 1/16'exist between opening and frame.Max shim stack is 1140.Shims shall be load-bearing and capable of transferring leads to the substrate.
<br /> 9.When used in areas requiring Impart protection,this product REQUIRES the use of approved impact resistant shullers or other external protection.
<br /> 10.Sealing and Dashing by others should be applied using the ASTM E 2112 methodology appropriate for the opening into which the product Is being Installed.Overall water penetration resistance of the installed product is
<br /> not addressed In this drawing and Is the responsibility of others.
<br /> 11.Glazing shag comply with ASTM E 1300.
<br /> 12.All fasten s penetrabng Into pressure treated wood shall be capable of preventing conusbn due to reaction with pressure treatment chemicals.Any dissimilar materials that cane Into contact shall be protected to
<br /> prevent reactions In accordance With code requirements.
<br /> 13.A wind load duration factor Cd m 1.6 was used for the analysis of wood screws only.
<br /> 14.Products shall be constructed es specified in test reports A9243.01-50147 and A4934.01-50147 by Architectural Testing,Inc-Springdale,PA and G4256.01-10947,B3423.01-10947,COB27.0140947,
<br /> C0838.01-109-47,C5W8.01-10947 and C7754.01-10947 by Architectural Testing,Inc-York,PA.
<br /> 15.Use 100%pure silicone caulk compliant with AAMA 800 Section 1-Sealant Specifications for use with Architectural Fenestration Products.Make sure surfaces are completely free horn ail m old cauk daaged wood,
<br /> wood fibers,grease,oil did,rust,mold or similar contaminants.Vacuum and clean opening surfaces completely.A fully primed surface is recommended,but not required.Cleaning of all surfaces should be done the
<br /> same day of which the silicone caulk is to applied.For more delags visit Simontan.com.
<br /> 16,Caulk application:recommended at and surface temperatures at the time of application are to be between 40 and 90 degrees F.Insure all contact surfaces are clean and dry Including the new window(s).Use a backer
<br /> rod on all joints>3141 deep ondlarwiderthan 1/4'.Finished ceulkjoint should be a minimum of 3/6'deep and make full contact with both the newwindim and structural opening surfaces.Silicone caulk should be
<br /> forced into joint or CompmssGd to assure full Contact on both surfaces and to expel any air pockets.
<br /> AIERIAL• 1E ON Ev.
<br /> -1m �SIMONTON' B IN0254 6
<br /> m,+mmmme i+Ina prWerty of simanl rmde.a..nie, s nshst� osnmvonnh iNmwcea
<br /> y 11Mwi 9Y. 0A
<br /> retoN+all prtprie[ary vnd rims rlgxlc to its sWFcl md[Im. _ ±aMmi+e eeecifiM
<br /> Tnls mmmml Is ProNmd to INe retlpknt m me e�premM OY h lO1PFft 1 CademcAv®v lIM a
<br /> —Um
<br /> Nat N is ndl to Ice dbGoaM,repromad b Nde or n pSq,Y,+1,11! Offs®By:OA
<br /> prat,rim aced in cm},ntUon wu IHe dmigm,mmmt«lure m Oe Ind. Mgln
<br /> r.PaY of goods far mlyymm pm<r trim sl mkm wnm— SCNE: SHEET: APPRwo BE OAIE
<br /> tnouh its cdnsmt W.I.W.U.d«c not limit.. .x Z.p3 nT 2 of!
<br /> reCipiml•+H9Nt+to uIN..W—Um cmhoined h W. NFACE ANEA .ltx t.al a' 30 min. -ES