My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20159
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20159
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 2:39:51 PM
Creation date
5/28/2019 2:39:50 PM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-20159
Building Department - Name
LENNAR HOMES LLC
Address
3229 KRESTERBROOKE LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Single Family_ Dwelling <br /> Plan Review Comments <br /> 1: F.F.E. shall be a minirnum:of 8- above.the road.elevation and an engineered.site plan. <br /> 2.- Lots shall be graded.to-comply with R401.3 of the F.B:C: <br /> .3.: Compaction:test required.if 24" or more of fill dirt"is brought in: any one place: <br /> 4 Tie in survey regquired before pouring concrete.' <br /> 5.1 Driveways require-a R.,O.:W. use permit.: All 4:sides of driveway thru the-sidewalk shall have. <br /> expansion material: <br /> 6- All setbacks shall.be <br /> 'met.: . <br /> 7. All property markers shall be uncovered and marked.at time of first 'inspection: <br /> 8: All A.D.A. requirements.shall be met.: . <br /> 9.. No:electric;plumbing,.mechanical;,or framing shall be covered without an inspection and <br /> approval first. . <br /> 10. All Garages shall-comply:with section R302.6:of the F.B.C.(Fire Separation)., <br /> 11:Appliances:shall not be installed in:-A-location where'subj ect to me'echanical damage unless. <br /> protected by approved barriers. M303.4 of.the F.B.C. <br /> 12. Water heaters shall comply,with sectionP607.3 of the F:B.C: <br /> 13. Foundation supports for AIC.units shall be raised at least 3"above finished grade. M1308.1. <br /> 14. Return air in all.bedrooms..F.B.C. .M_1620.4_: <br /> .-15: Smoke detectors are to be iristalled_in accordance.with R3111 of the.F.B.C. <br /> 16:All glazing requirements are.16 be-in accordance with R308.4 of the.F.B.C. <br /> 17. All means,of egress are to:be in:accordance with R311 of the F;B.C. :: <br /> 18. "Green gypsum:board shall not be used.as.a backer.irishowers ortubs.R702.4:2.F.B:C. <br /> 19. Combination-type AFCI breakers are required.at all locations requiring.an AFC1.type breaker: <br /> 20: Carbon monoxide alarms will.be required in.new:construction.that uses fossil-burningheating <br /> or appliances or an attached garage: They shall be,installed in accordance with the F,B.C:. <br /> 21. All plumbing, mechanical,.and electrical shall-be separate from unit to.unit: This includes all. <br /> underground plumbing and electric: <br /> 22. All 2016.N.E.C. Codes:will.be enforced-.. <br /> 23.Tamper=Resistarit Receptacles in accordance with 406.11 of the 2016 N.E:C <br /> .24: In accordance:.with the Land:.Development:Code'.lots shall be sodded before final atleast 10 <br /> feet around the structure. : : :.. <br /> 25.Blower doortest and-blown in insulation card shall be provided before C:.O: <br /> 26 A copy of the enem eacls.shall'be with-nermit at all tinter <br /> 27.. Copy of final insulation report shall be:provided with perinit before.finab . <br /> F.F.E.-Finished Floor Elevation <br /> - F:B.C-Florida Building Code 6�'Edition <br /> K.O.W.-Right of Way. <br /> A.D:A:-Americans with Disabilities Act N.E.C.=National Electric.Code(2011) <br />
The URL can be used to link to this page
Your browser does not support the video tag.