Laserfiche WebLink
Single Family Dwelling <br /> Plan Review Comments <br /> 1: F.F:E.shall be a minimum of.8"above.the road elevation and an engineered site plan. <br /> 2_ Lots shall be graded to,comply with R401.3 of the F.R.C. <br /> p red if 24"or more of fill dirt is brought in=at any one place: . <br /> q <br /> Y q. <br /> 4. 'Tie n curve fret uired before pouring concrete. <br /> : 5.. Driveways:require a R.-OM. use permit:: All.4 sides of driveway-thru the sidewalk shall have <br /> expansion material-: <br /> material-: <br /> All setbacks.shall,be tnet.: . <br /> T. All property:markers shall be uncovered and marked at time of first'inspection: <br /> 8.. All A.D.A. fegiiirements shall be met. <br /> 9. No electric;plumbing, mechanical; or framing shall be covered without an inspection.and <br /> approval first., <br /> 10. All Garages shall.comply..with:section R302.6 of the F.B.C. (Fire Sbparation). <br /> 11; Appliances shall'not be installed in a location`where subject to,mechanical damage unless <br /> protected by approved,barriers. M303.4 of the F.B:C <br /> 12. Water heaters shall conriply with section:P607.3-of the F.R.C.- <br /> 13. Foundation supports for-A/C.units shall be raised at least 3" above finished grade.. M13'08.1 <br /> 14. Return air in all bedroorns.F.B.C. ,M1620.4.. <br /> 15. Smoke detOdfors'are to be installed.-in accordance:with R313.1 of the:F.B.C. <br /> 16: All glazing requirements are to be in_accordance with R308.4_of the RB:C. <br /> 17.'All means,of egress are to,be in:accordance with R311 of the RB.C. <br /> 18. "Green gypsum board"shall not be used:as.a backer.iri:showers or tubs.R702.4:2 F.B.C: <br /> 19..'Combination-type AFCI breakers are.required at all locations requiring an AF Cl,type breaker: <br /> 20: Carbon monoxide alarms-will be required in new-construction that uses fossil-burning heating <br /> or appliances or an attached garage.: They sh'I be,installed in de6ordance'with.the F.B.C. <br /> 21. All plumbing,mechanical,-and electrical shall:be separateā€¢from unit,to unit: This-includes all <br /> underground plumbing and electric: <br /> 22. All 2016:N.E:C: Codes.will be enforced.. <br /> .23:Tamper= Resistant Receptacles in accordance with 406.11 of the 2016 N.E:C. . <br /> 24: In accordance:with the* Land.Development:Code, lots shall be sodded before final at least 10 <br /> feet around.the structure. <br /> 25. Blower door test and blown iri insulation card shall be provided-before C:O: <br /> 26 A copy of the enemy cacls.shall'he with permit at all tinier. <br /> .27. Ccip of final insulation .eport shall be'prayided-with periiiit before.fnriL <br /> F.F.E.-Finished Floor.Elevation <br /> .F.B.C-Florida Building Code 601 Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans-with-Disabilities Act N.E.C.-National Electric Code-(2011) <br />