Laserfiche WebLink
Loads for Multiple Orientations Job: 3246E sf ADS Carrier <br /> Date: 712512018 <br /> lower floor By: Dave Aldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> Project Information <br /> For: Lennar Homes <br /> Design Conditions <br /> Location: Indoor: Heating Cooling <br /> Sarasota Bradenton, FL, US Indoor temperature(OF) 70 75 <br /> Elevation: 26 ft Design TD (OF) 38 17 <br /> Latitude: 27N Relative humidity 50 50 <br /> Outdoor: Heating Cooling Moisture difference(gr/lb) 33.1 63.0 <br /> Dry bulb(OF) 33 92 infiltration: <br /> Daily range(OF) - 14 L <br /> Wet bulb(OF) - 79 <br /> Wind speed(mph) 15.0 7.5 <br /> Front Door North Northeast East Southeast South Southwest West Northwest <br /> Sensible Load(Btuh) 18236 18066 15876 18268 :19771- 18539 15082 17697 <br /> Latent Load(Btuh) 1859 1859 1859 1859 1859 1859 1859 1859 <br /> Total Load(Btuh) 20095 19925 17735 20127 ,- 21630 20398 16941 19556 <br /> Heating AVF(cfm) 800 800 800 800 800 800 800 800 <br /> Cooling AVF(cfm) 800 800 800 800 "809i 800 800 800 <br /> Building Orientation Cooling Load <br /> 25000-- <br /> 20000� <br /> .2 <br /> 15000-- <br /> 0 <br /> 0 <br /> 0 <br /> 10000-- <br /> 5000-- <br /> 0 <br /> N NE E SE S sw w NW <br /> Direction Front Door faces <br /> Current Orientation: Front Door faces South <br /> Highest Cooling Load: Front Door faces South <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> -01-F wrightscft- 2018-Jul-25 14:03:36 <br /> Right-SuiteD Universal 201818.0.16 RSU05714 Page 2 <br /> ACCk ...pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJB Front Door faces: S <br />