My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20161
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20161
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 2:41:29 PM
Creation date
5/28/2019 2:41:27 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-20161
Building Department - Name
LENNAR HOMES LLC
Address
6424 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: 3246B sf ADS Carrier <br /> p p Date: 712512018 <br /> upper floor By: Dave Aldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> Project • • <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 92.3°F Sensible gain: 17510 Btuh Entering coil DB: 75.5°F <br /> Outdoor design WB: 78.8°F Latent gain: 3279 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 20789 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L <br /> Actual airflow: 800 cfm <br /> Sensible capacity: 20400 Btuh 117% of load <br /> Latent capacity: 3600 Btuh 110% of load <br /> Total capacity: 24000 Btuh 115% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 32.5°F Heat loss: 13445 Btuh Entering coil DB: 69.7°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L <br /> Actual airflow: 800 cfm <br /> Output capacity: 18852 Btuh 140% of load Capacity balance: 19 OF <br /> Supplemental heat required: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 800 cfm <br /> Output capacity: 4.0 kW 100% of load Temp. rise: 50 OF <br /> Meets all requirements of ACCA Manual S. <br /> wrightsoft- 2018-Jul-25 14:03:37 <br /> bw.b...... Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 <br /> ...pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces: S <br />
The URL can be used to link to this page
Your browser does not support the video tag.