My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20161
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20161
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 2:41:29 PM
Creation date
5/28/2019 2:41:27 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-20161
Building Department - Name
LENNAR HOMES LLC
Address
6424 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
e I�"R9 u Yeer�k <br /> ® � c a 0Jet Stream Ultra Blowing Wool Insulation KNAU ��C°JU�O� <br /> Attic and Cavity Wall Card - 1 1 �iwr�2+ �01gVe 1e+(Q1 <br /> Batts and Blankets Equipment Required <br /> When installed in accordance with the manufacturer's It is recommended that a pneumatic blowing machine and a corrugated hose with a minimum''/<"internal corrugation,a minimum length <br /> recommendations,Knauf Insulation batls and blankets will of 150'.Coils in the hose should not be Itess than 36'in diameter.Acceptable material feed rate is 5-35 lbs/minute.Recommended feed <br /> provide the full R-value. rate is 15-25 lbs/minute. <br /> R-Value* Minimum Thickness Thermal Performance(Sidewali and Attic Application) <br /> To obtain an The slated thermal resistance(R-value)is provided by installing in accordance with the manufacturer's instructions.Failure to install the <br /> insulation resistance Installed insulation should required number of bags per 1,000 square feet and exceeding the maximum square feet of coverage per bag as recommended by the label <br /> (R-value)of: not be less than: will result in lower installed R-values.Field blending of this product with other loose fill insulations is not recommended by the manufacturer. <br /> R-49 13.75" Cavity Wall Bag Net Weight-Nominal 32 lbs.,Minimum 31 lbs. <br /> R-38HD 10.25" <br /> R-38 12.00" R-Value* Bags per 1000 SF Maximum Net Minimum <br /> To obtain an The number of bags Coverage per Bag Weight per SF <br /> R-30HD 8.25" -Insulation per 1,000 square feet Contents of this The weight per square <br /> R-30 10.00" Cavity :resistance of net area should not bag should not feet of installed insulation <br /> R-26 9.00" Framing Depth of: Density be less than: cover more than: should not be less than: <br /> R-22 6.50" 2"x 4" 3:90" R-15 1.8 lbs./cu.ft. 16.4 bags 61.0 sq.ft. 0.525 lbs. <br /> R-21HD 5.50' 2"x 6" 5.50" R-23 1.8 lbs./cu.ft. 25.8 bags 38.8 sq.ft. 0.825 lbs. . <br /> R-19 6.25- 2"x 8" 7.25" R-31 1.8 lbs./cu.ft. 34.0 bags 29.4 sq.ft. 1.088 lbs. <br /> R-15HD 3.50° <br /> R-13 3.50" 2"x 10" 1 9.25" 1 R-39 1.8 lbs./cu.ft. 43.4 bags 23.1 sq.ft. 1.388 lbs. <br /> R-11 3.50" R means resistance to heat flow.The higher the R-value,the greater the Insulating power.To get the marked R-value,it is essential that this insulation be installed property. <br /> R-8 2.50" <br /> "R-19 in a 5.5'cavity.Conforms IoASTM C 665 and Federal Open Attic Application Bag Net Weight-Nominal 32 lbs.,Minimum 31 lbs. <br /> Specification HH-1.521 F. Minimum <br /> Bags/ Maximum Minimum Initial Settled <br /> Framing Adjustment 1,000 SF Coverage Weight Installed Thickness** <br /> To compensate for framing members,the number of bags per The number of bags/ Contents of this The weight/SF Thickness Contents of this <br /> 1,000 sq,ft.of area to be insulated should be as shown below. R-Value* 1,000 SF of net area bag should not of installed Installed insulation bag should <br /> Ba s/MSF Ba S/MSF To obtain an insulation should not be less cover insulation should not should not be less not cover more <br /> 9 9 resistance(R-Value)of: than: more than: be less than than: than: <br /> Joist 16"O.C. 24"O.C. R-60 29.7 33.6 SF .952 lbs. 19.750" 19.750' <br /> R-Value Dimensions Framing Framing <br /> 2x4 29.2 29.4 R-49 23.5 42.5 SF .753 lbs. 16.375" 16.375" <br /> R-60 2x6 28.9 29.1 R-44 20.9 47.8 SF .670 lbs. 14.875" 14.875" <br /> 2x8 28.6 28.9 R-38 17.8 56.2 SF .569 lbs. 13.000" 13.000" <br /> 2x4 23.0 23.2 R-30 13.6 73.3 SF .437 lbs. 10.375" 10.375" <br /> R-49 2x6 22.7 22.9 R-26 11.8 85.0 SF .377 lbs. 9.125" 9.125" <br /> 2x8 22.4 22.7 R-22 9.8 102.2 SF .313 lbs. 7.750' 7.750" <br /> 2x4 20.4 20.6 <br /> R-44 2x6 20.1 20.3 R-19 8.4 119.3 SF .268 lbs. 6.750" 6.750" <br /> 2x8 19.8 20.1 R-13 5.7 175.3 SF .183 lbs. 4.750" 4.750" <br /> 2x4 17.3 17.4 R-11 4.7 210.8 SF .152 lbs. 4.000" 4.000" <br /> R-38 2x6 17.0 17.2 Bag Net Weight-Nominal 32 M.,Knimum 31 Pis. <br /> 2x8 16.7 17.0 Coverage and instagation data were detem fined using a Volu-Matid II blowing machine In thW gear wdh 13'gate opening,2.0 psi air pressure and 150'of 3'IntemallytroLmgated hose. <br /> This producl conforms to the performance requirements ofASTM C 764,Type I,and cancelled Federal Specification HH4.1030B,Type I,Class B.R-values are determined in accordance Wth C 667 and C 518. <br /> 2x4 13.2 13.3 •'R'means resistance to heat flow.The higher the R-value,the greater the insulating power.To gel the marked R-value,it is essential that this insulation be inswed property.If you do tyounelf,get instruc- <br /> R-30 2x6 12.9 13.1 tions and follow them carelu0y.Instructions do not come MLh this package. <br /> "Based on TMrd Party 2-year setting study,the predicted set0ement over a 20-yearpenod would be 1 percent or less.This amount of se"is thermally insignificant.Therefore,the installed and setled <br /> 2x8 12.6 12.9 thicknesses are etedivel the same. <br /> 2x4 11.3 11.4 Voh Maticgl is a registered Irsdemark of Uniwl. <br /> R-26 2x6 11.0 11.2 Builder's Insulation Statement <br /> 2x8 10.8 11.0 Jet Stream Ultra has been installed in conformance with the included recommendations to provide a thermal resistance of... <br /> 2x4 9.3 9.5 R-Value Thickness <br /> R-22 2x6 9.1 9.3 Attic Area R- at Inches <br /> 2x8 1 8.8 9.1 Sloped Ceilings R- at Inches <br /> 2x4 7.9 8.1 Walls R- at Inches <br /> R-19 2x6 7.7 7.9 <br /> 2x8 7.4 7.7 Floors(over an unheated crawl space) R- at Inches <br /> 2x4 5.3 5.4 Crawl Space Perimeter R- at Inches <br /> R-13 2x6 5.0 5.2 Date Installed <br /> 2x8 4.8 6.0 Blown insulation has been installed in conformance with the above recofnmendations to provide an R-value of: <br /> 2x4 4.3 4.4 R- )6 using .��bags of this insulation to cover/ _square feet of area <br /> R-11 2x6 4.1 4.3 at a minimum thickness of s. <br /> 2x8 3.8 4.1 <br /> �r1� UL Errv1n"men/ Insulation Contractor(signature) <br /> GREENGUARD Gold- <br /> Kne"r Insulomon bultdi g m.vlmi°n e&i..d Company Date <br /> UL Envhonmwr GREENGUARD Gdd-d it <br /> UL EWronmenl rolidmed to be formaldehyde free <br /> UL E,Wmnmem GREENGUARD Home Builder(signature) <br /> 0 CeMfi,wi-Progrom- <br /> Pmdode aro eero6ed w UL Envtmnme,n <br /> GREENGUARD slwdard,1w bw d mic°t Company Date <br /> wr W.indoor air dvrirg pod-u."ae. <br /> Fw mom tnlormauon,riilr al.com/99 <br /> The coverage information on this Attic/Sidewall card applies to the entire United States,(including Minnesota). <br /> : .'- •! ;- www.knaufinsulation:us. Knauf Insulation,Inc. One Knauf Drive,Shelbyville,IN 46176 Tel:(800)825-0434 ext.8300 FAX:(317)398-3675 <br /> ©2015 Knauf Insulation,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.